4.1.2
Remote Baud Rate
The remote communications baud rate and parity are programmed by the front panel
control in the Utility System menu (refer to
Chapter 3
). The programmed baud rate and
parity are maintained indefinitely in RAM on the M&C module. The parity bits can be
set to EVEN or ODD. The available baud rate are listed below:
•
150
•
300
•
600
•
1200
•
2400
•
4800
•
9600
•
19200
4.1.3 Remote
Address
To communicate with the established remote communications protocol, configure each
modem for one address between 1 and 255. Each modem on a common remote
communications link (EIA-485) must have a distinct address. Use the front panel control
in the
Function Select: Utility: System
menu (
Chapter 3
) to program the address.
An EIA-485/EIA-232 communications link remotely controls and monitors all modem
functions. Use the 2- or 4-wire, half-duplex EIA-485 interface to connect between two or
more modems and switches on a common communications link. Use the EIA-232
interface to communicate with a single modem.
Note:
Address 0 is reserved as a global address which simultaneously addresses all
devices on a given communications link.