SLM-3650 Satellite Modem
Revision 3
Operation
MN/SLM3650.IOM
3–49
3.4.12
Function Select: Remote AUPC
To view or change the Remote AUPC functions, enter the Remote AUPC menu from the
Function Select menu on the front panel. After entering the Remote AUPC menu, press
[
←
] or [
→
] to select the Configuration or Monitor menu. Enter the selected menu by
pressing [ENTER]. Press [
←
] or [
→
] to view the selected configuration parameters.
Note:
This is only available with the ASYNC/AUPC overhead option.
3.4.13
Function Select: Remote AUPC: Remote AUPC Configuration
Refer to Figure 3-15.
AUPC ENABLE
Programs the AUPC feature ON or OFF.
Upon entry, the current status of the remote AUPC is displayed. Press [
↑
] or [
↓
]
to make the selection. Press [ENTER] to execute the change.
Note:
This program is for control or last known status.
B-BAND LOOPBACK
Programs the remote baseband loopback ON or OFF.
Upon entry, the current status of the remote baseband loopback is displayed.
Press [
↑
] or [
↓
] to make the selection. Press [ENTER] to execute the change.
Note:
This program is for control or last known status.
TX 2047 PATTERN
Programs the remote TX 2047 pattern ON or OFF.
Upon entry, the current status of the remote TX 2047 is displayed. Press [
↑
] or
[
↓
] to make the selection. Press [ENTER] to execute the change.
Note:
This program is for control or last known status.
3.4.13.1
Function Select: Remote AUPC: Remote AUPC Monitor
Refer to Figure 3-16.
2047 ERRORS
Receive 2047 BER. This is a monitor point that displays the current RX 2047
BER. If no data is available, “No Data” is displayed.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com