SDM-300A Satellite Modem
Operation
Rev. 4
3–45
3.3.11 Stored
Faults/Alarms
Refer to Figure 3-14.
The modem stores the first 10 (Flt0 through Flt9) occurrences of fault status changes in
each of the following major fault categories:
•
Modulator
•
Demodulator
•
Transmit Interface
•
Receive Interface
•
Common Equipment
•
Backward Alarms (IDR option only)
Each fault status change is stored with the time and date of the occurrence of the fault.
Stored faults may be viewed by entering the stored faults level from the Select menu.
Refer to Sections 3.1.3.9.1 through 3.1.3.9.6 for fault explanations. UNAVAL
SECONDS fault information appears in Section 3.1.3.10.1.
Stored faults are not maintained through controller power-on reset cycle. However, the
last known time is maintained in nonvolatile Random Access Memory (RAM). On
power-up, a common equipment fault is logged (Flt0) with that last known time and date.
In addition, on power-up, an additional common equipment fault is logged (Flt1) to
indicate the power-up time and date. The power-down and power-up times are logged as
common equipment fault 0 and common equipment fault 1, respectively.
On entering the stored faults level, press [
←
] or [
→
] to move between the fault groups
and the “Clear Stored Faults ?” selections. The time and date of the first stored fault
status (Flt0) for the selected group will be displayed alternately on line 2 of the display.
Press [
↑
] or [
↓
] to cycle through the selected group has stored fault status (Flt0 through
Flt9). To display the fault status associated with the displayed time and date, press
[ENTER]. To identify the fault, press [
←
] or [
→
] to move the flashing cursor. To clear
the currently logged stored faults, press [ENTER] when the “Clear Stored Faults/Yes?”
selection is displayed.
Note: Faults are stored in time sequence, with the oldest fault status change stored in
Flt0, and the most recent in Flt9. Only the first 10 fault status changes are stored. All
stored faults, which have not been used, indicate “No Fault” on the display.
3.3.11.1 Unavailable
Seconds
Fault
UNAVAL SECONDS
x
A fault is indicated if the Reed-Solomon Codec could not correct bit errors
in one block of serialized data in any given second.
Note: This is available only with the Reed-Solomon option.
Summary of Contents for SDM-300A
Page 33: ...Introduction SDM 300A Satellite Modem 1 14 Rev 4 This page is intentionally left blank...
Page 57: ...Operation SDM 300A Satellite Modem 3 4 Rev 4 This page is intentionally left blank...
Page 78: ...SDM 300A Satellite Modem Operation Rev 4 3 25 This page is intentionally left blank...
Page 96: ...SDM 300A Satellite Modem Operation Rev 4 3 43 This page is intentionally left blank...
Page 101: ...Operation SDM 300A Satellite Modem 3 48 Rev 4 This page is intentionally left blank...
Page 118: ...SDM 300A Satellite Modem Operation Rev 4 3 65 This page is intentionally left blank...
Page 169: ...Theory of Operation SDM 300A Satellite Modem 4 18 Rev 4 This page is intentionally left blank...
Page 189: ...Maintenance SDM 300A Satellite Modem 5 20 Rev 4 This page is intentionally left blank...
Page 205: ...Options SDM 300A Satellite Modem A 16 Rev 4 Figure A 3 E1 Framing Formats...
Page 206: ...SDM 300A Satellite Modem Options Rev 4 A 17 Figure A 4 T1 Framing Formats...
Page 237: ...Options SDM 300A Satellite Modem A 48 Rev 4 Figure A 10 IDR Interface Block Diagram...
Page 241: ...Options SDM 300A Satellite Modem A 52 Rev 4 Figure A 11 IBS Interface Block Diagram...
Page 257: ...Options SDM 300A Satellite Modem A 68 Rev 4 CBA Figure A 19 Reed Solomon Codec Installation...
Page 265: ...Options SDM 300A Satellite Modem A 76 Rev 4 Figure A 24 8 Channel Multiplexer Installation...
Page 273: ...Options SDM 300A Satellite Modem A 84 Rev 4 Figure A 26 Flex Mux Multiplexer Installation...
Page 275: ...Options SDM 300A Satellite Modem A 86 Rev 4 This page is intentionally left blank...
Page 330: ...SDM 300A Satellite Modem Remote Control Operation Rev 4 B 55...
Page 388: ...Specifications SDM 300A Satellite Modem C 58 Rev 4 This page is intentionally left blank...
Page 392: ...Glossary SDM 300A Satellite Modem g 4 Rev 4 This page is intentionally left blank...
Page 398: ...Index SDM 300A Satellite Modem i 6 Rev 4 This page is intentionally left blank...