SDM-300A Satellite Modem
Options
Rev. 4
A–79
A.3.4 Flex
Mux
Flex Mux (Figure A-25) PCB is offered as a factory or field installable interface.
Simultaneous operation of a main data channel and three overhead channels are
supported. The main data channel is a G.703 type electrical interface at E1 (2048 kbit/s)
or T1 (1544 kbit/s) terrestrial data rate and supports both pass through and D&I modes of
operation. AUPC, ASYNC data and voice channels are supported in the three overhead
channels.
•
Channel (Main Data) # 1: G.703 E1 or T1
•
Channel (Overhead) # 2: ADPCM (Audio)
•
Channel (Overhead) # 3: EIA-232, EIA-422, or AUPC
•
Channel (Overhead) # 4: EIA-232, EIA-485 or AUPC
Flex Mux is designed to plug into the base board of the modem at two internal interfaces,
and provide a single 50-pin “D” sub-connector at the rear of the modem to replace the
non-overhead 25-pin connector. The particular overhead configuration of
the PCB is
determined by software control via the front panel.
Connection to external terrestrial equipment is supplied through a 50-pin “D” sub-
connector located at the rear of the modem. The unit is compatible with the Comtech
EFData:
•
SMS-7000 switch
•
SMS-301 switch
•
UB-300 universal breakout panel
A 96-pin DIN connector and a 30-pin DIP header supply interface to the internal circuitry
of the base modem. These connectors provide data flow, control, status and power
between the modem and the unit.
User control and status monitoring of the unit via the front panel or the EIA-232 or
EIA-485 remote port (J6) located on the back of the modem.
Refer to the following tables for system specification:
•
Table A-23. System Specifications
•
Table A-24. Multiplexer Specifications
•
Table A-25. Demultiplexer Specifications
Note: The Flex Mux Channel 1, D&I, will operate with other modems set-up for D&I as
long as Channels 2, 3, and 4 are Off.
Summary of Contents for SDM-300A
Page 33: ...Introduction SDM 300A Satellite Modem 1 14 Rev 4 This page is intentionally left blank...
Page 57: ...Operation SDM 300A Satellite Modem 3 4 Rev 4 This page is intentionally left blank...
Page 78: ...SDM 300A Satellite Modem Operation Rev 4 3 25 This page is intentionally left blank...
Page 96: ...SDM 300A Satellite Modem Operation Rev 4 3 43 This page is intentionally left blank...
Page 101: ...Operation SDM 300A Satellite Modem 3 48 Rev 4 This page is intentionally left blank...
Page 118: ...SDM 300A Satellite Modem Operation Rev 4 3 65 This page is intentionally left blank...
Page 169: ...Theory of Operation SDM 300A Satellite Modem 4 18 Rev 4 This page is intentionally left blank...
Page 189: ...Maintenance SDM 300A Satellite Modem 5 20 Rev 4 This page is intentionally left blank...
Page 205: ...Options SDM 300A Satellite Modem A 16 Rev 4 Figure A 3 E1 Framing Formats...
Page 206: ...SDM 300A Satellite Modem Options Rev 4 A 17 Figure A 4 T1 Framing Formats...
Page 237: ...Options SDM 300A Satellite Modem A 48 Rev 4 Figure A 10 IDR Interface Block Diagram...
Page 241: ...Options SDM 300A Satellite Modem A 52 Rev 4 Figure A 11 IBS Interface Block Diagram...
Page 257: ...Options SDM 300A Satellite Modem A 68 Rev 4 CBA Figure A 19 Reed Solomon Codec Installation...
Page 265: ...Options SDM 300A Satellite Modem A 76 Rev 4 Figure A 24 8 Channel Multiplexer Installation...
Page 273: ...Options SDM 300A Satellite Modem A 84 Rev 4 Figure A 26 Flex Mux Multiplexer Installation...
Page 275: ...Options SDM 300A Satellite Modem A 86 Rev 4 This page is intentionally left blank...
Page 330: ...SDM 300A Satellite Modem Remote Control Operation Rev 4 B 55...
Page 388: ...Specifications SDM 300A Satellite Modem C 58 Rev 4 This page is intentionally left blank...
Page 392: ...Glossary SDM 300A Satellite Modem g 4 Rev 4 This page is intentionally left blank...
Page 398: ...Index SDM 300A Satellite Modem i 6 Rev 4 This page is intentionally left blank...