HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Revision 9
Serial-Based Remote Product Management
5–10
MN/HPOD.IOM
NOTE
– Instruction Code Qualifiers, as defined in
Sect. 5.4.2.5
, are used in the command/query tables ‘
Response to Command
’
columns:
=
Message OK
*
Message OK, but not permitted in current mode
?
Received OK, but invalid arguments found
#
Message OK, but unit is not in
Remote
mode
!
Invalid instruction
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to
Query
Auto Fault
Recovery
AFR=
1 byte,
value of 0,
1
Command or Query.
Automatically mutes SSPA output in the event of detected fault.
If enabled, it causes the output to go active (un-mute) if all faults
are cleared. If disabled, output remains muted even if all faults
are cleared.
Example:
<1/AFR=1’cr’
>0001/AFR=’cr’’lf’
AFR=
AFR?
AFR*
AFR?
AFR=x
(See
Description
of
Arguments)
RF Power
Amplifier
State
AMP=
1 byte,
value of 0, 1
Command or Query.
Turn ON or OFF the RF power amplifiers, in the form x, where:
0 = Off
1 = On
Example:
<1/AMP=1’cr’
AMP=
AMP?
AMP*
AMP?
AMP=x
(See
Description of
Arguments)
Attenuation
ATT=
5 bytes,
numerical
Command or Query.
Set a valid attenuation level, in 0.25 dB increments, in the form
xx.xx.
Example:
<1/ATT=12.25’cr’
ATT=
ATT?
ATT*
ATT?
ATT=xx.xx
(See
Description of
Arguments)
Gain Offset
GOF=
5 bytes,
numerical
Command or Query.
Set or query the adjusted attenuation level, in 0.25 dB
increments, in a 1:1 redundant system so power is equal
between the online and offline units when a switchover occurs, in
the form xx.xx.
Example:
<1/GOF=02.00’cr’
GOF=
GOF?
GOF*
GOF?
GOF =xx.xx
(See
Description of
Arguments)
Summary of Contents for HPOD
Page 10: ...MN HPOD IOM Revision 9 Table of Contents TOC viii MN HPOD IOM BLANK PAGE...
Page 16: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Preface vi MN HPOD IOM Notes...
Page 27: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Introduction 1 11 MN HPOD IOM Notes...
Page 138: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix A A 39 MN HPOD IOM Notes...
Page 151: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix B B 12 MN HPOD IOM Notes...
Page 158: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix C C 7 MN HPOD IOM BLANK PAGE...
Page 159: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix C C 8 MN HPOD IOM Notes...
Page 160: ......
Page 161: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...