HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Revision 9
Ethernet-Based Remote Product Management
4–7
MN/HPOD.IOM
3)
Enter the User name and password (the default for both is
comtech
):
Use the
LRS
remote command to set the Ethernet remote control access parameter:
Use
default
remote command
LRS=3
for
Ethernet control
Use remote command
LRS=2
for
Ethernet control only
.
4)
If necessary, use the
IPA
remote command to set a unique IP address.
1)
Each HPOD must have a unique IP address assigned before
connection to a network. If the IP address needs to be changed from
the factory default setting, use the IPA=xxx.xxx.xxx.xxx.yy remote
command, where ‘xxx.xxx.xxx.xxx’ is a valid IP address on the
network where the unit will be installed, and ‘yy’ is the range
(typically, yy=24).
2)
If you change the IPA value, make sure to shut off and restart the
unit; then, start a new Telnet session using the new IP address.
Summary of Contents for HPOD
Page 10: ...MN HPOD IOM Revision 9 Table of Contents TOC viii MN HPOD IOM BLANK PAGE...
Page 16: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Preface vi MN HPOD IOM Notes...
Page 27: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Introduction 1 11 MN HPOD IOM Notes...
Page 138: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix A A 39 MN HPOD IOM Notes...
Page 151: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix B B 12 MN HPOD IOM Notes...
Page 158: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix C C 7 MN HPOD IOM BLANK PAGE...
Page 159: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix C C 8 MN HPOD IOM Notes...
Page 160: ......
Page 161: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...