HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Revision 9
Introduction
1–9
MN/HPOD.IOM
Spurious
Second Harmonic
-60 dB dBc max @ 1 dB below rated output
Optional BUC LO
Leakage
-20 dBm
Input
Impedance
50
Ω
Noise Figure
8 dB typical, 10 dB maximum @ maximum gain (15 dB for HPOD Ku-Band)
with BUC Option
25 dB
VSWR
1.25:1 Maximum
with BUC Option
1.50:1 Maximum
Connector
Type ‘N’
Sample Ports
Output Sample
Type N, 50
Ω
, -40 dBc nominal
Input Sample
Type N, 50
Ω
, -20 dBc nominal
Remote Control
COM Port
EIA-485 or EIA-232
Alarms
Summary Fault
Form C
Environmental
Operating Temp.
-40° to +55°C (-40° to 131°F)
Non-operating Temp.
-50° to +75°C (-58° to 167°F)
Operating Humidity
0% to 100% condensing
Altitude
10,000 ft above sea level (derated 2°C/ 1000 ft AMSL)
Power Requirements
180 to 264 VAC, 47 Hz to 63 Hz (typical)
Physical
Dimensions
26.77L x 17.88W x 11.49H inches (67.99L x 45.41W x 29.18H cm)
Weight
75 lbs. (34 kg) nominal
Available Options
Optional BUC
Summary of Contents for HPOD
Page 10: ...MN HPOD IOM Revision 9 Table of Contents TOC viii MN HPOD IOM BLANK PAGE...
Page 16: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Preface vi MN HPOD IOM Notes...
Page 27: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Introduction 1 11 MN HPOD IOM Notes...
Page 138: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix A A 39 MN HPOD IOM Notes...
Page 151: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix B B 12 MN HPOD IOM Notes...
Page 158: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix C C 7 MN HPOD IOM BLANK PAGE...
Page 159: ...HPOD C X Ku Band High Power Outdoor Amplifier Revision 9 Appendix C C 8 MN HPOD IOM Notes...
Page 160: ......
Page 161: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...