CRS-280/280-L IF Switch for 1:N Redundancy
Revision -
Cables and Connections
4–2
MN-CRS-280/280L
4.2
Control Cable Connections
Each CRS-280/280L is supplied with a control cable for connection to the associated 1:N
Redundancy Switch control unit. The control cable must be specified at time of order:
1: N Redundancy Switch
CEFD Part No.
Description
SMS-7000**
CA/5343-1
Control Cable, DB-15F
DB-15M, 8’
CRS-400**
CA/WR0066
Control Cable, DB-25M
DB-25F, 6’
CRS-300
CRS-500
CA-0021666
Control Cable, DB-9F
DB-25M, 8’
** Indicates a Comtech EF Data legacy product that is no longer in production.
1. When connecting the Control cable between the CRS-280L and the
redundancy switch, ensure that screw locks on the ‘D’ type connectors are
securely fastened. This will prevent the accidental unmating of the cable,
particularly when a standby unit is being removed or replaced.
2. Only one control interface must be used. Do not make connections to both
control interfaces on the CRS-280L. The CRS-280L automatically detects
the control interface in use and cannot function with both control cables
connected.
Connect the supplied cable between the Redundancy Switch (controller) and the CRS-280/280L
(refer to the pertinent Redundancy Switch
Installation and Operation Manual
for additional
information):
For CRS-280/280L
Refer to:
SMS-7000 1:8 Modem Protection Switch**
Sect. 4.2.1
CRS-400 1:8 HSSI Redundancy Switch**
Sect. 4.2.2
CRS-300 1:N Redundancy Switch
Sect. 4.2.3
CRS-500 M:N Redunancy System
Sect. 4.2.4