CRS-280/280L IF Switch for 1:N Redundancy
Revision -
Connector Pinouts
3–6
MN-CRS-280/280L
3.2
Front Panel Connectors
Unless otherwise noted, the connectors featured on the front panel of the CRS-280/280L are
intended for connection to all IF equipment internal and external to the 1:N redundancy setup.
3.3
Rear Panel Control Connectors
Unless otherwise noted, the connectors featured on the rear panel of the CRS-280/280L are
intended for connection to the companion redundancy switch control interface.
3.3.1
CRS-280 Switch Control Interface Connector
3.3.1.1 J1 CRS Control Interface Connector, DB-25F
The 25-pin ‘D’ Type female (DB-25F)
J1 CRS Control Interface
connector is used to connect the CRS-280L to the
IF Switch Control
port, located on the CRS-230 Controller card installed in the CRS-400
1:8 Redundancy Switch or CRS-300 1:10 Redundancy Switch, or to the
P1 IF Switch Control
port located on the control interface side of the CRS-500 M:N Redundancy
System’s Data Switch Unit (DSU).
The Comtech EF Data CRS-400 1:8 Redundancy Switch is a legacy product that is
no longer in production.
The J1 CRS Control Interface
connector communicates with the logic interface of the
companion redundancy switch to drive the currently selected terrestrial modem, and to decide
whether the system is in bridged or backup mode. The CRS-280L performs the same bridging
and backing up functions of the Tx and Rx IF signals to match what the companion redundant
switch does to the terrestrial data signals.
Summary of Contents for CRS-280