CDM-740 Advanced Satellite Modem
Revision 0
Rear Panel Connector Pinouts
MN-CDM740
3–6
3.5
Power / Ground Connections
3.5.1
Alternating Current Power Connector
A standard, detachable, non-locking, 3-prong power cord (IEC
plug) supplies the Alternating Current (AC) power to the modem
via this connector.
Note the following:
AC Power Specifications
Input Power
40W maximum, 20W typical
Input Voltage
100 - 240 volts AC, +6%/-10% - autosensing
(total absolute max. range is 90 - 254 volts AC)
Connector Type
IEC
Fuse Protection
5.0A Slow-blow (115 volt AC operation)
2.5A Slow-blow (230 volt AC operation)
Line and neutral fusing
(2) 20 mm type fuses
3.5.2
Direct Current (DC) Power Connector (Optional)
This optional connector supplies the Direct Current (DC) power to
the modem.
Note the following:
DC Power Specifications
Input Power
48 watts (typical)
55 watts (maximum)
Input Voltage
48 volts DC, nominal
(36 volts to 60 volts)
Connector Type
Corcom PS series
Mating Connector
Corcom GA210 or Molex 03-12-1026
Fuse Protection
8A Slow-blow
Line and neutral fusing
(2) 20 mm type fuses
3.5.3
Chassis Ground Connector
A #10-32 stud adjacent to the power connector is used for connecting a common
chassis ground among equipment.
Note:
The AC power connector provides the safety ground.
Summary of Contents for CDM-740
Page 2: ......
Page 8: ...This page is intentionally blank...
Page 24: ...CDM 740 Advanced Satellite Modem Revision 0 Preface MN CDM740 xviii Notes...
Page 38: ...CDM 740 Advanced Satellite Modem Revision 0 Introduction MN CDM740 1 14 Notes...
Page 42: ...CDM 740 Advanced Satellite Modem Revision 0 Installation MN CDM740 2 4 Notes...
Page 84: ...CDM 740 Advanced Satellite Modem Revision 0 Front Panel Operation MN CDM740 5 32 Notes...
Page 114: ...CDM 740 Advanced Satellite Modem Revision 0 Ethernet Management MN CDM740 6 30 Notes...
Page 138: ...CDM 740 Advanced Satellite Modem Revision 0 Remote Control MN CDM740 A 24 Notes...
Page 150: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...