1.3 Sensor
Specifications
Current Sensor
Current range
0-600 A (DC)
Relative precision on Range
± 1%
Max Linearity error
± 0.9 % of reading
Band Width at ±1db
2.5 Khz
Voltage Sensor
Voltage range
0-100 V (DC)
Relative precision on Range
± 1%
Max Linearity error
± 0.5 % of reading
Band Width at ±1db
2.5 Khz
Pressure Sensor
English Units
Metric Units
Pressure range
2.5 – 14.5 PSI
15 – 100 Kpa
Relative precision on Range
± 3%
± 3%
Max Linearity error
± 1.8 % of reading
± 1.8 % of reading
Band Width at ± 1db
250 Hz
250 Hz
Wire Speed Sensor
English Units
Metric Units
Wire diameter (min/max)
.030 - .062 inch
0.8 mm / 1.6 mm
Speed range
10 – 1000 ipm
4 – 420 mm/s
Relative precision on Range
± 3%
± 3%