The following is a summary of the two special command functions. They are
used to set and read the Micro ADM™ Real Time Clock (RTC). To read the
current Time type the following command:
From Host type:
T? (cr)
Response from Micro ADM™:
hh:mm:ss
Where: hh is the current hour, mm is the current
minute and ss is the current second. (cr) is
the enter key
To set the time (hour/minute/second) type:
T=10:17:35
(cr) Entire field must be
completed as explained below:
Type 6:45 am as
T=06:45:00 (cr)
Type 7:25 PM as
T=19:25:00 (cr)
Note: “cr” denotes carriage return (Enter)
To read the current Date type the following command:
From Host type:
D? (cr)
Response from Micro ADM™:
mn:dd:yy
Where: mn is the current month, dd is the current
day and yy is the current year, (cr) is the
enter key
To set the date (year/month/day) type:
D=99/06/01
(cr). The Entire field must be
completed as explained below:
Type February 4, 1999 as
D=99/02/04(cr)
Type November 23, 2000 as
D=00/11/23(cr)
Note: “cr” denotes carriage return (Enter)
15
Summary of Contents for Micro ADM
Page 2: ......
Page 35: ...A 8 NetHub Mounting Dimensions 31...
Page 42: ...Appendix B Micro ADM Assembly Parts List B 1 Micro ADM Sensor Assembly P N A3A0226 Rev 0 38...
Page 43: ...39...
Page 45: ...B 2 Micro ADM Sensor Assembly P N A3A0226 Rev A 41...
Page 46: ...42...
Page 48: ...B 3 Micro ADM Sensor Assembly P N A3A0226 Rev B 44...
Page 49: ...45...
Page 51: ...B 4 Micro ADM Sensor Assembly P N A3A0226 Rev C 47...
Page 52: ...48...