Compu Pool E-Series Manual
15
8.5
Wiring
8.5.1
WARNING: Before wiring ensure that the power is turned off at the source.
8.5.2
Power must also be shut off at the Chlorinator circuit breakers before performing
any wiring. Be sure to follow local and NEC electrical codes.
8.5.3
The Electronics Module inputs and outputs are indicated with labels on the
enclosure as shown below.
8.5.4
Figure 2: Electronics Module Inputs and Outputs
8.5.5
The single phase input (220-240VAC) is not provided with a pre-wired cable, this
will need to be installed into the electronics module through the liquid tight cable
gland provided. The E-Series unit will need to be connected to the power source
with a cable that meets local and National Electrical Code(s). The 220-240VAC
input must be connected by carrying out the following procedure by a qualified
electrician.
01. Lift up the Circuit Breaker Door and
remove the two screws (M4) holding the
door in place.
02. Remove the Circuit Breaker Access
Panel by removing the four screws (M4)
and pulling outwards.