Compu Pool E-Series Manual
17
8.5.6
The ORP input is not provided with a pre-wired cable, this will need to be installed
into the electronics module through the liquid tight cable gland provided if required.
The wires need to be connected to the ORP 110V AC relay as shown in Figure 3.
The wires can be connected to either terminal. Conversion kits for 24VAC and
240VAC ORP inputs are also available as a spare part.
8.5.7
Connect the two Cell Output cables to the cell head in the manner shown in the
image below. Place the cable terminal between the brass washers and nuts. Using
two wrenches tighten the nuts (24mm flats) together firmly with a torque of
approximately 60 foot pounds (80 newton meters). Do not tighten the brass nuts
down onto the cell head as this may damage the part.
8.5.8
Connect the Water Flow Sensor cable to the input socket.
8.5.9
A bonding terminal is located on the metal electrical enclosure of this device (see
8.5.3). To reduce the risk of electrical shock, this terminal must be connected to the
grounding means provided in the electrical supply.
8.5.10 WARNING: Installation of electrical wiring should only be performed by a qualified
electrician. Failure to do so could result in serious harm and electrocution.