If the compressor is anchored to the base on which it is installed, the tilt angle with respect to
the horizontal surface must not exceed 7°. Install the compressor in a facility where precip-
itation cannot reach. Choose a facility for installing the compressor with a minimum level of
dust. Install the compressor at least 1,5 m from walls.
If multiple compressors are installed, there should be a 1,5 m minimum distance between
each compressor. There should be a 4 m safety distance from the area of the operated equip-
ment connected to the compressor. The facility in which the compressor is installed must be
fitted with a combined extract-and-input ventilation system.
The facility where the compressor is installed should be provided
with air inflow equivalent to twice the compressor’s capacity.
The volume of extraction ventilation must not exceed 40% of the air inflow capacity of the input
ventilation in a facility where the compressor is installed and fitted with an extract- and input ven
-
tilation system.
The compressor should not be installed in a facility where the temperature may drop below +5°С.
In order to extract hot air flowing out the compressor, an air duct may be used that is up to 3 m in
length and with a cross section 20% larger than that of the air-outflow orifice from the compressor’s
radiator. If an air duct longer than 3 m is used, additional duct fans should be used.
3.4 Connection to the compressed airline
Provide the throughput capacity of the compressed-air line in accordance with the perfor-
mance of the compressor. In order to avoid damage associated with seal failure of the com-
pressed-air line, the compressor should be connected via a flexible hose. All components of
the compressed-air line must have a working pressure no less than the compressor’s nominal
pressure. Use a pressure vessel with a capacity corresponding to the compressor’s perfor-
mance and the compressed air consumer.
3.5 Connecting to power supply
The compressor is not supplied with a power cable. The cable size must be chosen to ensure
that the maximum voltage drop not exceed 5 %
of the nominal voltage value. Cable length
must not exceed 25 m. Ambient temperature in the facility must not exceed 40°C. The cable
must be sheathed with a fire retardant compound. An isolating switch must be fitted within
reach of the compressor to facilitate connection
and maintenance.
Summary of Contents for AV-Series
Page 62: ...Comprag Comprag...
Page 64: ...64 1 1 1 1 1 1 2...
Page 65: ...65 COMPRAG AV 1 2 3 Comprag 4 5 6 1 3 1 2 3...
Page 66: ...66 1 1 4 5 6 7 8 9 10 11 12...
Page 67: ...67 COMPRAG AV 1 4 1 2 3 4 5 6 90 A 7 8...
Page 68: ...68 1 1 1 5 1 2 3 4 5 6 7 8 1 3 9 9 10 10 11 12 13...
Page 69: ...69 COMPRAG AV 14 15 16 17 18 19...
Page 72: ...72 1 1 2 4 2 3 4 5 3 6 8 13 6 16 6 15 14 13 14 2 5 1 6 5 2 7 3 4 2 5...
Page 73: ...73 COMPRAG AV v Log 6 1 2 1 3 2 5 7 3 6 3 2 5 100...
Page 74: ...74 1 1 2 6 Fig 2 6 AV75 90 1 4 YA 1 2 QS CT2 I P R C RC SB Tr F1 F2 v LOG FI H...
Page 77: ...77 COMPRAG AV 3 3 3 3 AV75 90 1 2 3 7 5 C 40 C 40 1500 1500 1500 1500 1500 1 2...
Page 78: ...78 1 1 3 4 3 5 5 25 3 5 1 1 2 3 2...
Page 79: ...79 COMPRAG AV 2 2 6 3 4 4 1 AV75 90 v LOG...
Page 80: ...80 1 1 4 1 1 v Log 4 1 2 4 1 1...
Page 82: ...82 1 1 H 0000H 0000H 0000H 0000H 1 0000H 0000H 5 01 40 03 CK0968 M0003 UTFCE123456789A 60...
Page 85: ...85 COMPRAG AV 105 C 3 5 112 C 3 000 0 2 2 008 2BAR 000 0 2 VSD VSD...
Page 87: ...87 COMPRAG AV 4 2 10 LCD 4 3 10 LCD...
Page 88: ...88 1 1 5 5 1 TO 1 TO 2 TO 3 TO 2 500 2000 4000 6000 6000 2 3 2000...
Page 89: ...89 COMPRAG AV 5 2 1 1 1 1 5 3 1 5 2 5 3...
Page 90: ...90 1 1 V75 8 700 10 700 V90 8 700 10 700 5 4 1 2 1 5 4 1 5 4 2 2 2 1 1 2 1...
Page 91: ...91 COMPRAG AV 5 5 2 1 5 5 1 2 3 4 1 2 3 4 1 2 5 6 5 6 4 1 2 2 3 2 4 5 3 4...
Page 92: ...92 1 1 5 7 2 1 5 7 1 5 8 2 5 8 90...
Page 93: ...93 COMPRAG AV 5 9 5 5 5 10 D2 0 005...
Page 94: ...94 1 1 6 6 1 5 3 5 3 5 40 5 2 5 8 13 13...
Page 95: ...95 COMPRAG AV 7 7 1 20 35 85 7 2...
Page 96: ......