Ensure that the floor of the facility can withstand the weight of the compressor. Install the
compressor on a level surface that is able to bear its weight. Adjust the horizontal axis of the
compressor using a levelling instrument. If the compressor is not anchored to the base on
which it is installed, the tilt angle with respect to the horizontal surface must not exceed 3°.
If the compressor is anchored to the base on which it is installed, the tilt angle with respect
to the horizontal surface must not exceed 7°. Install the compressor in a facility where pre
-
cipitation cannot reach. Choose a facility for installing the compressor with a minimum level
of dust. Install the compressor at least 1.5 m from walls.
If multiple compressors are installed, there should be a 1.5 m minimum distance between
each compressor. There should be a 4 m safety distance from the area of the operated equip
-
ment connected to the compressor. The facility in which the compressor is installed must be
fitted with a combined extract-and-input ventilation system.
The facility where the compressor is installed should be provided
with air inflow equivalent to twice the compressor’s capacity.
The volume of extraction ventilation must not exceed 40% of the air inflow capacity of the
input ventilation in a facility where the compressor is installed and fitted with an extract-and-
input ventilation system. The compressor should not be installed in a facility where the tempera-
ture may drop below +5°С. In order to extract hot air flowing out the compressor, an air duct
may be used that is up to 3 m in length and with a cross section 20% larger than that of the
air-outflow orifice from the compressor’s radiator. If an air duct longer than 3 m is used, ad
-
ditional duct fans should be used.
3.4 Connection to the compressed airline
Provide the throughput capacity of the compressed-air line in accordance with the perfor-
mance of the compressor. In order to avoid damage associated with seal failure of the com-
pressed-air line, the compressor should be connected via a flexible hose. All components
of the compressed-air line must have a working pressure no less than the compressor’s
nominal pressure. Use a pressure vessel with a capacity corresponding to the compressor’s
performance and the compressed air consumer.
Summary of Contents for 11410101
Page 74: ...Comprag Comprag...
Page 76: ...76 1 4 1 1 1 1 2 1 2 3 Comprag...
Page 77: ...77 COMPRAG F 4 5 6 1 3 1 2 3 4 5 6 7 8...
Page 78: ...78 1 4 9 10 11 1 4 1 2 3 4 5...
Page 79: ...79 COMPRAG F 6 90 A 7 8 1 5 1 2 3 4 5 6...
Page 80: ...80 1 4 7 8 9 10 11 12 13 14 15 16 17 18 19...
Page 85: ...85 COMPRAG F 2 4 2 3 1 2 3 2 4 5 3 6 8 13 6 16 6 13 14 2 5 1 2 3 4 5 2 5 t Log...
Page 91: ...91 COMPRAG F 3 7 0 C 40 C 40 3 4...
Page 93: ...93 COMPRAG F 3 3 5 2 2 6 3 4 4 1 F5 5 F 22 t LOG...
Page 94: ...94 1 4 LEDs t Log 4 1 1...
Page 95: ...95 COMPRAG F LED COMPRAG 5 C C01 bar C01...
Page 96: ...96 1 4 M1 A 0 0 B 0 0 C 0 0 h m h m h m h m 0110h 0110h 0110h 0110h M1 0110h 0110h...
Page 98: ...98 1 4 5 2bar 8 0bar 0300s 0001 0099h 0016 6 0bar 8 0bar...
Page 100: ...100 1 4 4 2 99 C C01 00 C 0 C01 M1 104 8A...
Page 101: ...101 COMPRAG F C 112 C 8 4bar 105 C 0110h 0110h 0110h 0110h...
Page 102: ...102 1 4 4 3 4 4 10 5 5 1 TO 1 TO 2 TO 3 TO 2 500 2000 4000 6000 6000 2 3 2000...
Page 103: ...103 COMPRAG F 5 2 1 5 2 1 5 3 5 6 1 5 3...
Page 105: ...105 COMPRAG F 2 2 1 1 2 1 5 5 1 2 5 5 1 2...
Page 106: ...106 1 4 5 6 1 2 5 6 2 1 2 2 5 3 4 1 5 7 5 7 C 1...
Page 107: ...107 COMPRAG F 5 8 1 5 8 1 90 5 9 5 5 5 10 D2 x0 005 M...
Page 108: ...108 1 4 6 6 1 5 3 5 3 5 40 5 2 5 8 13 13 7 7 1 20 50 85 7 2...