3-12
Diagnostic Tools
POST Error Messages
Continued
Error Code
Audible Beeps
L=Long S=Short
Probable Source of Problem
Recommended Action
1778-Drive Array
resuming Automatic
Data Recovery
process
None
This message appears whenever
a controller reset or power cycle
occurs while Automatic Data
Recovery is in progress.
No action necessary.
1779-Drive Array
Controller detects
replacement drives
None
Intermittent drive failure and/or
possible loss of data.
If this message appears and drive
X
has not been replaced, this indicates
an intermittent drive failure. This
message also appears once
immediately following drive
replacement whenever data must be
restored from backup.
1780-Disk 0 Failure
None
Hard drive/format error.
Run Diagnostics. Replace failed
assembly as indicated.
1781-Disk 1 Failure
None
Hard drive/format error.
Run Diagnostics. Replace failed
assembly as indicated.
1782-Disk Controller
Failure
None
Hard disk drive circuitry error.
Run Diagnostics. Replace failed
assembly as indicated.
1784-Drive Array
Drive Failure,
Physical Drive
None
Defective drive and/or cables.
Check for loose cables. Replace
defective drive
X
and/or cable(s).
1785-Drive Array not
Configured
None
Configuration error.
Run the System Configuration Utility
and correct.
1786-Drive Array
Recovery Needed
The following
drive(s) need
Automatic Data
Recovery: Drive
X
.
Select "F1" to
continue with
recovery of data to
drive(s).
Select "F2" to
continue without
recovery of data to
drive(s).
None
Interim Data Recovery
mode. Data has not been
recovered yet.
Press
F1
key to allow Automatic Data
Recovery to begin. Data will
automatically be restored to drive
X
now that the drive has been replaced
or now seems to be working.
-Or-
Press the
F2
key and the system will
continue to operate in the Interim Data
Recovery mode.
Continued