3-5
Compaq ProLiant 800 Servers Maintenance and Service Guide
POST Error Messages
Continued
Error Code
Audible Beeps
L=Long S=Short
Probable Source of Problem
Recommended Action
162-System
Options Not Set
2S
Configuration incorrect.
Run the System Configuration Utility
and correct.
163-Time & Date
Not Set
2S
Invalid time or date in
configuration memory.
Run the System Configuration Utility
and correct.
170- Expansion
Device Not
Responding
None
EISA or PCI expansion
board failure.
Check board for secure installation.
Replace the failed board if necessary.
172- Configuration
Nonvolatile
Memory Invalid
None
Nonvolatile configuration
corrupt or jumper installed.
Run the System Configuration Utility
and correct.
172-1 Configuration
Nonvolatile
Memory Invalid
None
Nonvolatile configuration
corrupt.
Run the System Configuration Utility
and correct.
172-2 IRC
Configuration Invalid
None
IRC enabled and video
controller is in PCI slot on the
secondary bus.
Move video controller to a PCI slot on
the primary PCI bus.
173- Slot ID
Mismatch
None
Board replaced, configuration
not updated.
Run the System Configuration Utility
and correct.
174-
Configuration/Slot
Mismatch Device
Not Found
None
EISA or PCI board not found.
Run the System Configuration Utility
and correct.
175-
Configuration/Slot
Mismatch Device
Found
None
EISA or PCI board added,
configuration not updated.
Run the System Configuration Utility
and correct.
176-Slot with Not
Readable ID Yields
Valid ID
None
EISA or PCI board in slot that
should contain an ISA board.
Run the System Configuration Utility
and correct.
177-Configuration
Not Complete
None
Incomplete System
Configuration.
Run the System Configuration Utility
and correct.
178-Processor
Configuration Invalid
None
Processor type or step does not
match configuration memory.
Run the System Configuration Utility
and correct.
179-System
Revision Mismatch
None
A board was installed that has a
different revision date.
Run the System Configuration Utility
and correct.
180-Log Reinitialized
None
N/A
N/A
Continued