109 - 02
CMOS clock rollover test
failed
109 - 03
CMOS clock test, CMOS not
properly initialized
-----------------------------------------------------------------------------
Error
Recommended
Code
Description
Action
-----------------------------------------------------------------------------
110 - 01
Programmable timer load
Replace the processor board
data test failed
and retest for error codes
103 - xx through 114 - xx.
110 - 02
Programmable timer dynamic
test failed
110 - 03
Programmable Timer No. 2
load data test failed
111 - 01
Refresh detect test failed
112 - 01
Speed test slow mode out
of range
112 - 02
Speed test mixed mode out
of range
112 - 03
Speed test fast mode out
of range
112 - 04
Speed test unable to enter
slow mode
112 - 05
Speed test unable to enter
mixed mode
112 - 06
Speed test unable to enter
fast mode
112 - 07
Speed test system error
112 - 08
Speed test unable to enter
auto mode
-----------------------------------------------------------------------------
Error
Recommended
Code
Description
Action
-----------------------------------------------------------------------------
112 - 09
Speed test unable to enter
Replace the processor board
high mode
and retest for error codes
103 - xx through 114 - xx.
112 - 10
Speed test high mode out
of range
112 - 11
Speed test auto mode out
of range
112 - 12
Speed test variable speed
mode inoperative
112 - 13
Failed Cache speed test