1782 - Disk
None
Fixed disk drive
1.
Run Diagnostics.
Controller
controller error
2.
Check and/or
Failure
replace the power
distribution board.
3.
Replace the fixed
disk drive.
-----------------------------------------------------------------------------
Message
Beeps
Probable Cause
Recommended Action
-----------------------------------------------------------------------------
1790 - Disk 0 Error
None
Fixed disk drive
1.
Run Diagnostics.
error or wrong
2.
Replace the
drive type
drive.
-----------------------------------------------------------------------------
1791 - Disk 1 Error
None
Fixed disk drive
1.
Run Diagnostics.
error or wrong
2.
Replace the
drive type
drive.
-----------------------------------------------------------------------------
XX000Y ZZ Parity
None
Parity RAM
Run Diagnostics.
Check 2
failure
-----------------------------------------------------------------------------
Audible
1 Short
Power on
None.
successful
-----------------------------------------------------------------------------
Audible
2 Short
Power on
None.
successful
-----------------------------------------------------------------------------
(RESUME =
None
As indicated
Press F1 key
"F1" KEY)
to continue.
=============================================================================
Chapter 3.2 Diagnostic Error Codes