A-16
Compaq StorageWorks ESL9000 Series Tape Library Reference Guide
4
83
50
EXTENSION SENSOR FAIL
The CIG sensor was occluded unexpectedly during
calibration, inventory or pick/place. Retry the command.
If the failure recurs, contact your Compaq service
representative.
Both
4
84
00
VERTICAL INTERNAL FAILURE
Vertical axis code internal failure. Contact your Compaq
service representative.
Both
B
84
01
VERTICAL TIMEOUT
Vertical axis did not reach desired position within the
time limits. Retry command. If the failure recurs, run
vertical self-test.
Both
4
84
03
VERTICAL MECHANICAL POSITION ERROR
Vertical axis did not reach desired position. Retry
command. If the failure recurs, run vertical self-test.
Both
4
84
08
VERTICAL HOME NOT FOUND
Vertical axis did not reach the home position. Issue
REZERO UNIT and retry command. If the failure recurs,
run vertical self-test.
Both
B
84
10
VERTICAL INVALID ACTUATOR START POSITION
Position of vertical axis is unknown. Issue a REZERO UNIT
command.
Both
5
84
11
VERTICAL INVALID COMMAND
Vertical axis commanded to position out of library
mechanical limits. Issue a REZERO UNIT command. If the
problem persists, calibrate the library.
Both
4
84
20
VERTICAL TEST FAILURE
The value of the vertical encoder did not change during
the self-test. Check the motor/encoder connector.
Both
4
84
22
VERTICAL ENCODER FAILURE
The value of the vertical encoder did not change during
the self-test. Check the motor/encoder connector.
Both
Table A-4 Sense Data Values (Hexadecimal) (Continued)
Sense
Key
ASC
ASCQ
Message Name/Description
Interface