3-21
Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide
POST Error Messages
Continued
Error Code
Audible
Beeps
L=Long
S=Short
Probable Source of
Problem
Action
1786-Drive Array
Recovery
Needed
The following
drive(s) need
Automatic Data
Recovery: Drive
X
.
Select "F1" to
continue with
recovery of data
to drive(s).
Select "F2" to
continue without
recovery of data
to drive(s).
None
Interim Data
Recovery
mode. Data has not
been recovered yet.
Press
F1
key to allow
Automatic Data
Recovery to begin.
Data will automatically
be restored to drive
X
now that the drive has
been replaced or now
seems to be working.
-Or-
Press the
F2
key and
the system will
continue to operate in
the Interim Data
Recovery mode.
1787-Drive Array
Operating in
Interim Recovery
Mode.
Physical drive
replacement
needed: Drive
X
None
Hard drive
X
failed or
cable is loose or
defective. Following
a system restart, this
message reminds
you that drive
X
is
defective and fault
tolerance is being
used.
1. Replace drive X as
soon as possible.
2. Check loose cables.
3. Replace defective
cables.
*1788-Incorrect
Drive Replaced:
Drive
X
Drive(s)
were incorrectly
replaced: Drive
Y
Select "F1" to
continue - drive
array will remain
disabled.
Select "F2" to reset
configuration - all
data will be lost.
None
Drives are not
installed in their
original positions, so
the drives have
been disabled.
See
note below.
Reinstall the drives
correctly as indicated.
Press
F1
to restart the
computer with the
drive array disabled.
-Or-
Press
F2
to use the
drives as configured
and lose all the data
on them.