2-17
Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide
System I/O Board Cage
The system I/O board cage contains the system I/O board with PCI slots, system switches,
EISA slots, and the battery. Four slots are PCI/EISA; two are PCI only, for a total of six
slots.
To remove the system I/O board cage:
1.
Perform the preparation procedures. See page 2-2.
2.
Remove the top cover. See page 2-9.
3.
Disconnect all cables from the system I/O board cage.
4.
Remove any installed boards. Place them on a non-conductive work surface. You
will install them on the replacement system I/O board cage.
5.
Remove the two security screws (if installed).
6.
Push down on the cage ejector lever
➊
, and pull out
➋
.
7.
Pull the system I/O board cage out the back of the chassis
➌
.
1
2
3
Figure 2-14.
Removing the System I/O Board Cage
Reverse steps 1 through 7 to replace the system I/O board cage. Install any boards removed
in step 4 onto the replacement system I/O board cage.