4.
Layout and Function
4-1
fig. 4.1-1 CMM panels & Wall Mount unit.
Legend
1) CMM Panel for BAC units.
2) CMM for BAM units.
3) CMM Wall Mount unit to be added
to any existing high pressure
breathing air system.
NOTE: A purification chamber may be
needed for full functionality.
Consult
salesman for details.
4) Calibration Sample Gas Bottles.
The gas in these bottles is used to
calibrate the CMM unit. One of the
bottles contains “Pure Air” with no
CO and the other bottle contains
“Carbon
Monoxide””
with
a
CO
content of 20 PPM.
20 PPM sample gas bottle - Part #
003M4884-1
Pure Air sample gas bottle - Part #
009006-7800
4.1
General Description
Configurations
The
Mako
CMM
monitoring
systems
(See Fig. 4.1-1) incorporates the functions
required to check high pressure breathing air
for safe levels of Carbon Monoxide and
Moisture content.
There are two (2) possible CMM options.
1) CO Only
2) CO and MO
The CMM option provides monitoring of air for
unsafe levels of Carbon Monoxide (CO) and
Moisture (MO) content in PPM or parts per
million per unit volume.
The CO only
configuration measures carbon monoxide in
PPM and displayed in real-time as the
compressor system is running.
Danger!
Do not use CMM monitor for any application
other than with breathing air systems.
2
1
3
4