background image

G:\Masters\Installation Sheets\Master & Premier\MMR400S Aviation Installation Sheet.doc 

Page 3 of 18 

 

1. 

Conditions of use 

 

Read  this  manual  completely  before  working  on  or  making  adjustments  to  the  Compac 
equipment. 

 

Compac  Industries  Limited  accepts  no  liability  for  personal  injury  or  property  damage  resulting 
from working on or adjusting this unit incorrectly or without authorisation.  

 

Along with any warnings, instructions, and procedures in this manual, you should also observe 
any other common sense procedures that are generally applicable to equipment of this type. 

 

Failure  to  comply  with  any  warnings,  instructions,  procedures,  or  any  other  common  sense 
procedures  may  result  in  injury,  equipment  damage,  property  damage,  or  poor  performance  of 
the Compac equipment 

 

The major hazard involved with installing and operating the unit is electrical shock. This hazard 
can be avoided if you adhere to the procedures in this manual and exercise all due care. 

 

Compac  Industries  Limited  accepts  no  liability  for  direct,  indirect,  incidental,  special,  or 
consequential  damages  resulting  from  failure  to  follow  any  warnings,  instructions,  and 
procedures  in  this  manual,  or  any  other  common  sense  procedures  generally  applicable  to 
equipment of this type. The foregoing limitation extends to damages to person or property caused 
by the unit or damages resulting from the inability to use the unit including loss of profits, loss of 
products,  loss  of  power  supply,  the  cost  of  arranging  an  alternative  power  supply,  and  loss  of 
time, whether incurred by the user or their employees, the installer, the commissioner, a service 
technician, or any third party.  

 

Compac Industries Limited reserves the right to change the specifications of its products or the 
information in this manual without necessarily notifying its users. 

 

Variations  in  installation  and  operating  conditions  may  affect  the  unit's  performance.  Compac 
Industries Limited has no control over each installation's unique operating environment. Hence, 
Compac Industries Limited makes no representations or warranties concerning the performance 
of the unit under the actual operating conditions prevailing at the installation. A technical expert of 
your choosing should validate all operating parameters for each application. 

 

Compac Industries Limited has made every effort to explain all servicing procedures, warnings, 
and  safety  precautions  as  clearly  and  completely  as  possible.  However,  due  to  the  range  of 
operating environments, it is not possible to anticipate every issue that may arise. This manual is 
intended to provide general guidance. For specific guidance and technical support, contact your 
authorised Compac supplier, using the contact details in the Product Identification section 

 

Only parts supplied by or approved by Compac may be used and no unauthorised modifications to 
the hardware of software may be made. The use of non-approved parts or modifications will void 
all warranties and approvals. The use of non-approved parts or modifications may also constitute 
a safety hazard. 

 

Information  in  this  manual  shall  not  be  deemed  a  warranty,  representation,  or  guarantee.  For 
warranty provisions applicable to this unit, please refer to the warranty provided by the supplier. 

 

Unless otherwise noted, references to brand names, product names, or trademarks constitute the 
intellectual property of the owner thereof. Subject to your right to use the unit, Compac does not 
convey any right, title, or interest in its intellectual property, including and without limitation, its 
patents, copyrights, and know-how.  

 

Every effort has been made  to ensure the accuracy of this document. However, it may contain 
technical  inaccuracies  or  typographical  errors.  Compac  Industries  Limited  assumes  no 
responsibility  for  and  disclaims  all  liability  of  such  inaccuracies,  errors  or  omissions  in  this 
publication. 

Summary of Contents for Master MMR400S Aviation

Page 1: ...kland 1061 New Zealand PO Box 12 417 Penrose Auckland 1642 New Zealand Tel 64 9 579 2094 Fax 64 9 579 0635 info compac co nz www compac co nz Installation and Setup Instructions Model Master Version M...

Page 2: ...and Nozzles 8 9 1 Breakaways 8 10 Electrical Commissioning C4000 8 11 Mechanical Commissioning and Air Purge 9 12 Setting up the C4000 9 12 1 Configuration Codes 9 12 2 Submersible Delay Sd 10 12 3 Pr...

Page 3: ...stallation and operating conditions may affect the unit s performance Compac Industries Limited has no control over each installation s unique operating environment Hence Compac Industries Limited mak...

Page 4: ...G Masters Installation Sheets Master Premier MMR400S Aviation Installation Sheet doc Page 4 of 18 2 Footprint...

Page 5: ...al regulations The dispensing equipment shall be installed to prevent the delivery hose from contacting the ground when not in use Where local regulations require a sump to be fitted a Sumps must be p...

Page 6: ...es while working in the Flame proof box Operating the unit with these incorrectly set can result in damage to the C4000 Power Supply or incorrect operation of the solenoid These switches are set in th...

Page 7: ...sure ensure the sealing O ring is in place Note All cables entering the power supply must be glanded with approved 20mm flameproof glands Note Output to submersible pump s is 230 V ac 300 mA max It is...

Page 8: ...XD LED D6 will poll If the dispenser responds to polls for its respective pump number s Comms TXD LED D7 will also poll Diagnostic LED D18 slowly flashing If the dispenser is connected to an operation...

Page 9: ...eck all the dispenser fittings solenoids and pipework for leaks 7 Turn side A switch off and connect the hose to a suitable tank or container Turn side A switch on again 8 The display and tote should...

Page 10: ...elease the K factor switch repeatedly until Pcut appears on the Dollar display 3 Increase the Pcut setting and do another delivery Adjust the Pcut setting again if required The maximum value that the...

Page 11: ...the litres display and PrA is displayed on the money display 3 Press and hold the Parameter switch A digit of the displayed Price per litre will begin to increment 4 When the digit is correct release...

Page 12: ...Factor switch is shown in the diagram below J1 Comms Test J7 Displays J13 Not used J2 To Power Supply J8 Temperature for Temperature compensation only J14 Not used J3 Input from KG Meter Side A J 9 P...

Page 13: ...o a certified measuring container and compare the display value with the amount dispensed Example Display shows 10 00 True volume 20 00 To calculate the correct K Factor from the information above fir...

Page 14: ...roller If the pump is connected to a controller check that pump data and transaction information is being correctly uploaded to it Refer to the controller manual for specific instructions regarding co...

Page 15: ...exceeded Err 8 Excess reverse rotation of encoder Check product is not flowing back into the tank once the delivery has finished Err 9 Faulty or disconnected meter encoder 1 Check that encoder is plug...

Page 16: ...A K C4000 microprocessor board F CP C4PROCES A COM250 meter complete F METER COM250AS COM250 Flowmeter electronics F METER 125 250E ACV Valve P VALVE ACV 2 Solenoid Coil F D SCI08COIL10W C4000 Power...

Page 17: ...o the unit Phone number if dial in site Merchant ID number Eftpos site 21 Contact Details Service Agent Phone E mail Address 1 Address 2 22 Notes Manufacturer Contact Details The Compac Master Dispens...

Page 18: ...ation Sheet doc Page 18 of 18 23 Revision History Previous revision date Summary of changes New document 26 06 14 Added sump info in accordance with EPA File ref COM 09 29 Added Electrical and Mechani...