background image

G:\Masters\Installation Sheets\Master & Premier\MMR400S Aviation Installation Sheet.doc 

Page 10 of 18 

12.2 

Submersible Delay (Sd) 

  

This is the time delay from when the Submersible pump starts to when the  solenoids in the 
dispenser open to allow time for the leak detector to reset. 

 

This is factory set by Compac at 005 (five seconds).  
If problems are experienced with the leak detector tripping, firstly check that 'Sd' is still set and 
then, if necessary, make it longer as follows. 

 

1. Press and release the K factor switch repeatedly until 'Sd' appears on the Dollar display 
'dXXX' will appear in the litres display.  
 
2. Continue to press the K factor switch until the number to be changed flashes. Hold the switch 
down and this number will then increment. 
 
3. Release the switch when the required number is displayed. The value of the displayed number 
will then be stored in the C4000 memory as the Submersible delay. 
 

12.3 

Preset Cutoff (Pcut) 

 

If a preset keypad is fitted, it may be necessary to adjust the Pcut setting on site if the preset 
overruns. The Pcut setting turns the solenoid output (T3) off prior to the preset amount being 
reached to allow for preset overruns.    
 
1.

 

Do a preset delivery and observe if the preset overruns, and if so, by how much.  

2.

 

Press and release the K factor switch repeatedly until 'Pcut' appears on the Dollar display 

3.

 

Increase the Pcut setting and do another delivery. Adjust the Pcut setting again if required. 
(The maximum value that the Pcut can be set to is 9.99 litres). 

Notes: 
1.

 

The factory default setting is 0.00. When the Pcut is set to 0.00, the solenoid output (T3) 
turns off 0.5 litre before the preset amount, when changed from this, the solenoid turns off 
at the actual Pcut setting (x.xx litres). 

2.

 

Due to the high flow rate, it may not be possible to make the Pcut amount large enough to 
eliminate any preset overruns completely. 

 
 

12.4 

Parameter Switch settings 

12.4.1 

Setting the Pump Number  

This must be set at the pump, for each hose, so that communications with  
a controller can take place. The location of this switch is shown in the  
diagram below. 
Depress the Parameter Switch nine (9) or more times until the message  

'PnA XX' 

appears in the litres display window.  When the switch is  

pressed again 

'Pnb XX 

' will appear on the display. These two options 

 will toggle each time the switch is pressed. To alter either of the pump numbers, press and hold 
the Parameter Switch when the pump number to be altered appears on the display. This number 
will then increment. The switch should be released when the desired pump number is displayed. 
The value of the displayed number will then be stored in the C4000 memory as the pump 
number for that hose. 

NOTE

: For a single hose only 

‘Pn”

 will appear 

Summary of Contents for Master MMR400S Aviation

Page 1: ...kland 1061 New Zealand PO Box 12 417 Penrose Auckland 1642 New Zealand Tel 64 9 579 2094 Fax 64 9 579 0635 info compac co nz www compac co nz Installation and Setup Instructions Model Master Version M...

Page 2: ...and Nozzles 8 9 1 Breakaways 8 10 Electrical Commissioning C4000 8 11 Mechanical Commissioning and Air Purge 9 12 Setting up the C4000 9 12 1 Configuration Codes 9 12 2 Submersible Delay Sd 10 12 3 Pr...

Page 3: ...stallation and operating conditions may affect the unit s performance Compac Industries Limited has no control over each installation s unique operating environment Hence Compac Industries Limited mak...

Page 4: ...G Masters Installation Sheets Master Premier MMR400S Aviation Installation Sheet doc Page 4 of 18 2 Footprint...

Page 5: ...al regulations The dispensing equipment shall be installed to prevent the delivery hose from contacting the ground when not in use Where local regulations require a sump to be fitted a Sumps must be p...

Page 6: ...es while working in the Flame proof box Operating the unit with these incorrectly set can result in damage to the C4000 Power Supply or incorrect operation of the solenoid These switches are set in th...

Page 7: ...sure ensure the sealing O ring is in place Note All cables entering the power supply must be glanded with approved 20mm flameproof glands Note Output to submersible pump s is 230 V ac 300 mA max It is...

Page 8: ...XD LED D6 will poll If the dispenser responds to polls for its respective pump number s Comms TXD LED D7 will also poll Diagnostic LED D18 slowly flashing If the dispenser is connected to an operation...

Page 9: ...eck all the dispenser fittings solenoids and pipework for leaks 7 Turn side A switch off and connect the hose to a suitable tank or container Turn side A switch on again 8 The display and tote should...

Page 10: ...elease the K factor switch repeatedly until Pcut appears on the Dollar display 3 Increase the Pcut setting and do another delivery Adjust the Pcut setting again if required The maximum value that the...

Page 11: ...the litres display and PrA is displayed on the money display 3 Press and hold the Parameter switch A digit of the displayed Price per litre will begin to increment 4 When the digit is correct release...

Page 12: ...Factor switch is shown in the diagram below J1 Comms Test J7 Displays J13 Not used J2 To Power Supply J8 Temperature for Temperature compensation only J14 Not used J3 Input from KG Meter Side A J 9 P...

Page 13: ...o a certified measuring container and compare the display value with the amount dispensed Example Display shows 10 00 True volume 20 00 To calculate the correct K Factor from the information above fir...

Page 14: ...roller If the pump is connected to a controller check that pump data and transaction information is being correctly uploaded to it Refer to the controller manual for specific instructions regarding co...

Page 15: ...exceeded Err 8 Excess reverse rotation of encoder Check product is not flowing back into the tank once the delivery has finished Err 9 Faulty or disconnected meter encoder 1 Check that encoder is plug...

Page 16: ...A K C4000 microprocessor board F CP C4PROCES A COM250 meter complete F METER COM250AS COM250 Flowmeter electronics F METER 125 250E ACV Valve P VALVE ACV 2 Solenoid Coil F D SCI08COIL10W C4000 Power...

Page 17: ...o the unit Phone number if dial in site Merchant ID number Eftpos site 21 Contact Details Service Agent Phone E mail Address 1 Address 2 22 Notes Manufacturer Contact Details The Compac Master Dispens...

Page 18: ...ation Sheet doc Page 18 of 18 23 Revision History Previous revision date Summary of changes New document 26 06 14 Added sump info in accordance with EPA File ref COM 09 29 Added Electrical and Mechani...

Reviews: