IN1SMS[POE](C,U)_REV– 10/27/11 PAGE 7
INSTALLATION AND OPERATION MANUAL
CLFE4+1SMS[POE](C,U) SERIES
TECH SUPPORT: 1.888.678.9427
INSTALLATION INSTRUCTIONS
1 - SET DATA RATE DIP SWITCHES
Locate the 10/100 data rate DIP switch on the unit.
Set the data rate according to bandwidth required. The default setting for the data rate DIP switch is 100Mbps.
NOTE: The data rate must be set the same on both the local and remote units.
2 - SET WIRE PAIR DIP SWITCHES (UTP MODELS ONLY, FOR COAX MODELS SKIP TO STEP 3)
Locate the wire pair DIP switch on the unit.
Set the pair according to number of twisted wire pairs used (1 or 4). The default setting for the wire pair DIP switch is 4 pair.
NOTE: The number of pairs selected must be set the same on both the local and remote units.
3 - SET LOCAL/REMOTE DIP SWITCHES
Set the Local/Remote switch to Local (L) for Local (head end) devices or Remote (R) for Remote (field end) devices.
The default setting for this switch is Remote.
4 - SET MANAGED/UNMANAGED DIP SWITCHES
Set the Managed/Unmanaged switch to the “Managed” position. The default setting for this switch is Managed.
NOTE: In most cases, you will want to set the unit to “Managed” to prevent port flooding.
5 - CONNECT EXTENDED WIRING
Connect Extended Distance Port to field wiring.
6 - CONNECT NETWORK WIRING
Using CAT5/5e, connect Local unit to network and Remote unit to camera.
7 - CONNECT POWER
Connect power to unit per the following table:
Table 1 – Power Connections per Use Case
Non-PoE
PoE
Operating Voltage
9 to 15 VDC (9 VDC
†
when in C1 or C2)
†
48 to 56 VDC
Use Power Connectors
GND and +Vin
POE+ and POE-
Note: For the PoE models only use the PoE power connectors.
†
Contact the ComNet Design Center, or refer to the appropriate installation and operation manual when configuring and specifying power for a deployment.
8 - VERIFY FUNCTIONALITY
See LED table below and Troubleshooting Guide if corrective action is needed.
Table 2 – Indicating LEDs
PWR
POE
Link (Ethernet Port)
Activity (Ethernet Port)
EXT LNK
GREEN
Power Applied
PoE Applied
–
–
10M or 100M Link Detected
YELLOW –
–
Link Detected
–
–
OFF
Power Off
No PoE Present
No Link
–
No Link
BLINK
–
–
–
Data Activity
Data Activity