IN1SMS[POE](C,U)_REV–   10/27/11   PAGE 7

INSTALLATION AND OPERATION MANUAL 

CLFE4+1SMS[POE](C,U) SERIES

TECH SUPPORT: 1.888.678.9427

INSTALLATION INSTRUCTIONS

1 -   SET DATA RATE DIP SWITCHES

Locate the 10/100 data rate DIP switch on the unit. 

Set the data rate according to bandwidth required. The default setting for the data rate DIP switch is 100Mbps.

NOTE: The data rate must be set the same on both the local and remote units.

2 -   SET WIRE PAIR DIP SWITCHES (UTP MODELS ONLY, FOR COAX MODELS SKIP TO STEP 3)

Locate the wire pair DIP switch on the unit. 

Set the pair according to number of twisted wire pairs used (1 or 4). The default setting for the wire pair DIP switch is 4 pair.

NOTE: The number of pairs selected must be set the same on both the local and remote units.

3 -   SET LOCAL/REMOTE DIP SWITCHES

Set the Local/Remote switch to Local (L) for Local (head end) devices or Remote (R) for Remote (field end) devices.  

The default setting for this switch is Remote.

4 -   SET MANAGED/UNMANAGED DIP SWITCHES

Set the Managed/Unmanaged switch to the “Managed” position. The default setting for this switch is Managed.

NOTE: In most cases, you will want to set the unit to “Managed” to prevent port flooding.

5 -   CONNECT EXTENDED WIRING

Connect Extended Distance Port to field wiring.

6 -   CONNECT NETWORK WIRING

Using CAT5/5e, connect Local unit to network and Remote unit to camera.

7 -   CONNECT POWER

Connect power to unit per the following table:

Table 1 – Power Connections per Use Case

 

Non-PoE

PoE

Operating Voltage

9 to 15 VDC (9 VDC 

 when in C1 or C2)

48 to 56 VDC

Use Power Connectors

GND and +Vin

POE+ and POE-

Note: For the PoE models only use the PoE power connectors. 

 Contact the ComNet Design Center, or refer to the appropriate installation and operation manual when configuring and specifying power for a deployment.

8 -   VERIFY FUNCTIONALITY

See LED table below and Troubleshooting Guide if corrective action is needed.

Table 2 – Indicating LEDs

PWR

POE

Link (Ethernet Port)

Activity (Ethernet Port)

EXT LNK

GREEN

Power Applied

PoE Applied

10M or 100M Link Detected

YELLOW 

Link Detected

OFF

Power Off

No PoE Present

No Link

No Link

BLINK

Data Activity

Data Activity

Summary of Contents for CLFE4+1SMS[POE](C

Page 1: ...grammed preventing network video flooding with DIP switch selection of the fifth electrical port as uplink or as an unmanaged switch Ports 1 4 of the CLFE4 1SMSPOE can supply up to thirty 30 watts of...

Page 2: ...CE OR RACK MOUNT COAX UNIT WITH POE EXTENDED DISTANCE PORT 4 ETHERNET PORT 3 ETHERNET PORT 2 ETHERNET PORT 1 ETHERNET Operating Power 9 to 12 VDC non PoE 48 to 56VDC PoE Power Consumption 10W non PoE...

Page 3: ...ACK MOUNT UTP UNIT WITH POE FIGURE 4 CLFE4 1SMSPOEU FOUR CHANNEL SURFACE OR RACK MOUNT UTP UNIT WITH POE Operating Power 9 to 12 VDC non PoE 48 to 56VDC PoE Power Consumption 10W non PoE 130W Max PoE...

Page 4: ...NIT FIGURE 6 CLFE4 1SMSC FOUR CHANNEL SURFACE OR RACK MOUNT COAX UNIT EXTENDED DISTANCE PORT 4 ETHERNET PORT 3 ETHERNET PORT 2 ETHERNET PORT 1 ETHERNET Operating Power 9 to 15 VDC Power Consumption 10...

Page 5: ...THERNET FIGURE 7 CLFE4 1SMSU FOUR CHANNEL SURFACE OR RACK MOUNT COAX UNIT FIGURE 8 CLFE4 1SMSU FOUR CHANNEL SURFACE OR RACK MOUNT UTP UNIT Operating Power 9 to 15 VDC Power Consumption 10W Black w Whi...

Page 6: ...systems as illustrated Please contact ComNet s Design Center to discuss your specific requirements Ethernet Connection PoE Power Extended Connection PoE Camera PoE Camera PoE Camera PoE Camera Ethern...

Page 7: ...ED UNMANAGED DIP SWITCHES Set the Managed Unmanaged switch to the Managed position The default setting for this switch is Managed NOTE In most cases you will want to set the unit to Managed to prevent...

Page 8: ...on a short cable to eliminate possibility of faulty cabling Check that the extended distance wire is connected to Extended Distance Port Verify that there is no additional equipment e g surge protect...

Page 9: ...ixing tab of the ferrite core to open it 2 Make three loops around the core with the power cable of the unit 3 Attach the ferrite core to the unit power cord as shown and press it until it clicks Lift...

Page 10: ...hey must be powered by an external 48 56VDC PSU IMPORTANT SAFEGUARDS A Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack env...

Reviews: