background image

IN1SMS[POE](C,U)_REV–   10/27/11   PAGE 10

INSTALLATION AND OPERATION MANUAL 

CLFE4+1SMS[POE](C,U) SERIES

FIGURE A

Dimensions are for a ComFit module

8.38cm

[3.3in]

2.7cm

[1.06in]

4.19cm

[1.65in]

0.8cm

[0.31in]

0.4cm

[0.16in]

0.62cm

[0.24in]

6.37cm

[2.50in]

13.2cm

[5.2in]

11.9cm

[4.7in]

15cm

[5.9in]

7.5cm

[2.9in]

0.63cm

[0.25in]

2.75cm

[1.1in]

44.45cm

[17.50in]

48.26cm

[19.0in]

15.44cm

[6.08in]

1.9cm

[0.75in]

4.37cm

[1.72in]

1.9cm

[0.75in]

INSTALLATION CONSIDERATIONS 

These units are supplied as Standalone/Rack mounted module. Units 

should be installed in dry locations protected from extremes of 

temperature and humidity.

WARNING

Unit is to be used with a Listed Class 2 power supply. Although 

the units may be mounted inside a ComNet rack the PoE models cannot be 

powered from the built-in rack PSU; they must be powered by an external 

48-56VDC PSU.

IMPORTANT SAFEGUARDS: 
A)  Elevated Operating Ambient

 - If installed in a closed or multi-unit rack 

assembly, the operating ambient temperature of the rack environment 

may be greater than room ambient. Therefore, consideration should be 

given to installing the equipment in an environment compatible with 

the maximum ambient temperature (T

ma

) specified by the manufacturer.

B)  Reduced Air Flow

 - Installation of the equipment in a rack should be such 

that the amount of air flow required for safe operation of the equipment 

is not compromised.

© 2014 Communication Networks. All Rights Reserved. “ComNet,” the “ComNet Logo,” “CopperLine,” 

and the “CopperLine Logo” are registered trademarks of Communication Networks.

3 CORPORATE DRIVE

 | 

DANBURY, CONNECTICUT 06810

 | 

USA

 | 

T: 203.796.5300

 | 

F: 203.796.5303

 | 

TECH SUPPORT: 1.888.678.9427

 | 

[email protected]

8 TURNBERRY PARK ROAD

 | 

GILDERSOME

 | 

MORLEY

 | 

LEEDS, UK LS27 7LE

 | 

T: +44 (0)113 307 6400

 | 

F: +44 (0)113 253 7462

 | 

[email protected]

Summary of Contents for CLFE4+1SMS[POE](C

Page 1: ...grammed preventing network video flooding with DIP switch selection of the fifth electrical port as uplink or as an unmanaged switch Ports 1 4 of the CLFE4 1SMSPOE can supply up to thirty 30 watts of...

Page 2: ...CE OR RACK MOUNT COAX UNIT WITH POE EXTENDED DISTANCE PORT 4 ETHERNET PORT 3 ETHERNET PORT 2 ETHERNET PORT 1 ETHERNET Operating Power 9 to 12 VDC non PoE 48 to 56VDC PoE Power Consumption 10W non PoE...

Page 3: ...ACK MOUNT UTP UNIT WITH POE FIGURE 4 CLFE4 1SMSPOEU FOUR CHANNEL SURFACE OR RACK MOUNT UTP UNIT WITH POE Operating Power 9 to 12 VDC non PoE 48 to 56VDC PoE Power Consumption 10W non PoE 130W Max PoE...

Page 4: ...NIT FIGURE 6 CLFE4 1SMSC FOUR CHANNEL SURFACE OR RACK MOUNT COAX UNIT EXTENDED DISTANCE PORT 4 ETHERNET PORT 3 ETHERNET PORT 2 ETHERNET PORT 1 ETHERNET Operating Power 9 to 15 VDC Power Consumption 10...

Page 5: ...THERNET FIGURE 7 CLFE4 1SMSU FOUR CHANNEL SURFACE OR RACK MOUNT COAX UNIT FIGURE 8 CLFE4 1SMSU FOUR CHANNEL SURFACE OR RACK MOUNT UTP UNIT Operating Power 9 to 15 VDC Power Consumption 10W Black w Whi...

Page 6: ...systems as illustrated Please contact ComNet s Design Center to discuss your specific requirements Ethernet Connection PoE Power Extended Connection PoE Camera PoE Camera PoE Camera PoE Camera Ethern...

Page 7: ...ED UNMANAGED DIP SWITCHES Set the Managed Unmanaged switch to the Managed position The default setting for this switch is Managed NOTE In most cases you will want to set the unit to Managed to prevent...

Page 8: ...on a short cable to eliminate possibility of faulty cabling Check that the extended distance wire is connected to Extended Distance Port Verify that there is no additional equipment e g surge protect...

Page 9: ...ixing tab of the ferrite core to open it 2 Make three loops around the core with the power cable of the unit 3 Attach the ferrite core to the unit power cord as shown and press it until it clicks Lift...

Page 10: ...hey must be powered by an external 48 56VDC PSU IMPORTANT SAFEGUARDS A Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack env...