IN1SMS[POE](C,U)_REV–   10/27/11   PAGE 2

INSTALLATION AND OPERATION MANUAL 

CLFE4+1SMS[POE](C,U) SERIES

TECH SUPPORT: 1.888.678.9427

FIGURE 1 – CLFE4+1SMSPOEC FOUR CHANNEL SURFACE OR RACK MOUNT COAX UNIT WITH POE

FIGURE 2 – CLFE4+1SMSPOEC FOUR CHANNEL SURFACE OR RACK MOUNT COAX UNIT WITH POE

EXTENDED 

DISTANCE

PORT 4 

ETHERNET

PORT 3

ETHERNET

PORT 2

ETHERNET

PORT 1 

ETHERNET

Operating Power:  9 to 12 VDC (non-PoE), 48 to 56VDC (PoE)
Power Consumption: 10W (non-PoE), 130W (Max PoE)

Black w/ White 
Stripe (GND)
Black (+Vin)

POE–
POE+

10/100 data rate DIP switch

Local/Remote DIP switch

Managed/Unmanaged DIP switch

See Installation Instructions

CLFE4+1SMSPOEC Front Panel

CLFE4+1SMSPOEC Rear Panel

Do not use for  

POE Applications.

Summary of Contents for CLFE4+1SMS[POE](C

Page 1: ...grammed preventing network video flooding with DIP switch selection of the fifth electrical port as uplink or as an unmanaged switch Ports 1 4 of the CLFE4 1SMSPOE can supply up to thirty 30 watts of...

Page 2: ...CE OR RACK MOUNT COAX UNIT WITH POE EXTENDED DISTANCE PORT 4 ETHERNET PORT 3 ETHERNET PORT 2 ETHERNET PORT 1 ETHERNET Operating Power 9 to 12 VDC non PoE 48 to 56VDC PoE Power Consumption 10W non PoE...

Page 3: ...ACK MOUNT UTP UNIT WITH POE FIGURE 4 CLFE4 1SMSPOEU FOUR CHANNEL SURFACE OR RACK MOUNT UTP UNIT WITH POE Operating Power 9 to 12 VDC non PoE 48 to 56VDC PoE Power Consumption 10W non PoE 130W Max PoE...

Page 4: ...NIT FIGURE 6 CLFE4 1SMSC FOUR CHANNEL SURFACE OR RACK MOUNT COAX UNIT EXTENDED DISTANCE PORT 4 ETHERNET PORT 3 ETHERNET PORT 2 ETHERNET PORT 1 ETHERNET Operating Power 9 to 15 VDC Power Consumption 10...

Page 5: ...THERNET FIGURE 7 CLFE4 1SMSU FOUR CHANNEL SURFACE OR RACK MOUNT COAX UNIT FIGURE 8 CLFE4 1SMSU FOUR CHANNEL SURFACE OR RACK MOUNT UTP UNIT Operating Power 9 to 15 VDC Power Consumption 10W Black w Whi...

Page 6: ...systems as illustrated Please contact ComNet s Design Center to discuss your specific requirements Ethernet Connection PoE Power Extended Connection PoE Camera PoE Camera PoE Camera PoE Camera Ethern...

Page 7: ...ED UNMANAGED DIP SWITCHES Set the Managed Unmanaged switch to the Managed position The default setting for this switch is Managed NOTE In most cases you will want to set the unit to Managed to prevent...

Page 8: ...on a short cable to eliminate possibility of faulty cabling Check that the extended distance wire is connected to Extended Distance Port Verify that there is no additional equipment e g surge protect...

Page 9: ...ixing tab of the ferrite core to open it 2 Make three loops around the core with the power cable of the unit 3 Attach the ferrite core to the unit power cord as shown and press it until it clicks Lift...

Page 10: ...hey must be powered by an external 48 56VDC PSU IMPORTANT SAFEGUARDS A Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack env...

Reviews: