15
interfacemode <port> <input-message> <output-message> on
For example: use
DC3 to receive external correction data, send the following command though
DC1:
Command
Description
com com3 9600
Match with external radio link rate.
interfacemode com3 auto auto on Auto detect the correction message type
Saveconfig
Save the setting to the receiver
4.2.2 Check the solution type
Send command to output GPGGA information to check the solution type:
log <port> gpgga ontime <frequency>
Frequency description: 1 (1 HZ); 2 (1 output every 2 seconds); 0.2 (5 HZ).
For example;
$GPGGA,<1>,<2>,<3>,<4>,<5>,<6>,<7>,<8>,<9>,M,<10>,M,<11>,<12>*hh<CR><LF>
$GPGGA,012827.00,3110.484867,N,12123.913553,E,4,05,1.4,39.4,M,8.012,M, 2.0,0031,*6E
<6> GNSS solution type
:
0=Fix not available
,
1=GPS FIX
,
2=RTD
,
4=RTK FIXED
,
5=RTK floating, 6=
Dead Reckong mode, 7= Manual input mode, 8= Super wide-lane mode,9= WASS MODE
4.3 Change the serial port baud rate
To check the baud rate, use the command:
log comconfiga
The reply is as follow: