ADCP-93-090 • Rev C • March 2021
Page 34
© 2021, CommScope, Inc.
c. Mark the cable to identify the blocking kit location as well as the front of the cable for
positioning of the Blocking Kit as shown in
Figure 35. 864-Fiber OSP Blocking Kit Position
6. Complete the OSP routing per
Note:
The final positioning of the 864-fiber Blocking Kit within the center portion of the
cable management channel of the OMX Splice Cabinet is critical. The Blocking Kit will
be positioned to allow room for additional cables and blocking kits within the central
channel of the OMX Splice Cabinet. Make sure that the bottom of the OSP blocking kit is
7-inches above the first splice tray location. If this dimension is any closer, there is a risk
of the oval tubing kinking and needs to be avoided.