ADCP-93-090 • Rev C • March 2021
Page 31
© 2021 CommScope, Inc.
2. Pre-install small cable ties into tie-down lances on the rear of the OMX Splice Cabinet by
inserting the cable tie through the tie-down lances and pulling the cable tie into the locking
end engaging the tie one or two clicks. Do this for all tray locations except the top four on
each side.
3. Cut corrugated tubing to 2.5” lengths and add to every position on the back wall of the
OMX cabinet (see
). Snug down the cable ties making sure not to crush the
corrugated tubing.
Figure 31. Cutting Corrugated Tubing
26090-A
TIE-DOWN
LACE
CORRUGATED
TUBING
WIRE
TIE
IFC
CABLE
OSP
CABLE
SECURE
1
2
3
4
FRONT VIEW