5. Alarms
User’s Manual for ION
®
-U Page
49
5. Alarms
5.1. Bite and Alarms
The Built-In Test concept comprises the monitoring of the power supplies, the power
amplifiers, fan units and the optical interface.
All occurring alarms can be checked via software at the Master Unit.
As soon as the software acknowledges a valid alarm, a message is transmitted to the
Master Unit.
If the reason for the alarm has been cleared or if the alarm should continue, a new
alarm message will not be repeated. If there was an interruption of at least five
seconds after acknowledgement, a new alarm message will be generated.
5.2. Troubleshooting
The status of the Remote Unit can be checked via the Master Unit (for details please
refer to the ION-U Site Manager software manual). Locally, the status can be
checked at the LED.
5.3. Status LED Alarms
For local supervision, a status LED on the connector flange of the Remote Unit
provides a visual indication of possible reasons for alarms.
The color of the LED
indicates the severity of the alarm. Detailed alarm information is available through the
ION-U software interface.
Status LED Indication
Alarms
Possible on-site measures
Green No
alarm
Status ok
Orange
Optical alarm Rx
Check fiber loss of optical link.
Check optical connectors.
Clean optical connectors.
(MU: Check optical output power
of corresponding OTRx at MU).
Red Hardware
failure
Reboot the RU via SM software or
reboot the RU by shortly
interrupting mains supply.
Status LED off
Mains
Check mains cabling.
Check mains power.