4. Commissioning
User’s Manual for ION
®
-U Page
29
4.3.6. Cleaning procedure for RF cable connectors
The figures in this chapter illustrate the cleaning procedure and do not show the
actual RU.
1. What is needed for the cleaning?
a. Isopropyl alcohol
b. Compressed air
c. Lint-free wipe
d. Cotton buds
2. Remove protective cap from the RF
connector.
Caution
: Risk of injury by flying particles when compressed air is used. Wear
protective clothing, especially protective glasses.
3. Remove metal chips and small
particles from the mating and inner
surfaces of the connector using
compressed air.
Warning
: Flammable material. Risk of fire. Keep away from sources of ignition.
Caution
: Eye irritant product. Risk of eye irritation. Avoid contact with eyes and skin.
Wear protective clothing, especially protective glasses.
4. Clean the connector winding with lint-
free wipe drenched with isopropyl
alcohol.