Ruckus ICX 7450 Switch Hardware Installation Guide
65
Part Number: 53-1003899-09
To display the temperature of a device, enter the
show chassis
command at any level of the CLI. The
show chassis
command displays
the current temperature, the power supply status, and temperature threshold levels. The displayed temperature reflects the temperature of
the board inside the device.
ICX7450-24 Switch#show chassis
The stack unit 1 chassis info:
Power supply 1 not present
Power supply 2 (AC - Regular) present, status ok
Model Number: 23-0000144-03
Serial Number: CZG2L23R04H
Firmware Ver: 32.65
Power supply 2 Fan Air Flow Direction: Front to Back
Fan 1 not present
Fan 2 ok, speed (auto): [[1]]<->2
Fan controlled temperature: 37.1 deg-C
Fan speed switching temperature thresholds:
Speed 1: NM<----->66 deg-C
Speed 2: 56<-----> 85 deg-C (shutdown)
Fan 2 Air Flow Direction: Front to Back
Slot 1 Current Temperature: 30.6 deg-C (Sensor 1), 37.3 deg-C (Sensor 2), 36.2 deg-C (Sensor 3), 30.1 deg-C
(Sensor 4)
Slot 2 Current Temperature: 30.5 deg-C (Sensor 1)
Slot 3 Current Temperature: 29.1 deg-C (Sensor 1)
Slot 4 Current Temperature: 29.5 deg-C (Sensor 1)
Warning level.......: 70.0 deg-C
Shutdown level......: 85.0 deg-C
Boot Prom MAC : c0c5.2059.e210
Management MAC: c0c5.2059.e210
ICX7450-24 Switch#