3.3
Secure the frame in the working position.
2
• Dome
• Base with O-ring system
• Cable attachment plate with tower, cable strain relief and
trays pre-installed (optional)
• Gel block with trigger
• Clamp
• 2 plugs for unused ports
• Silica gel
• Hook and loop fastener
• Tray wedge
• Hose clamps, felt tape
• Installation instruction
4-way gel block
Lower small ports 2 ports 8 - 22 mm
Upper large ports
2 ports 10 - 28 mm
If both the upper large ports are filled with the maximum cable diameter
(28 mm), the maximum cable diameter in the lower small ports becomes
20 mm.
2.2
Tools
• FACC-TUBE-STRIPPER-02 to strip loose tube
• ¼1/4” Nut driver
• 10 mm Nut driver
3.1
Remove the dome to base clamp. Remove the dome and
O-ring.
1
2
3
2.3
Accessories
• FOSC-A-Trays
• FOSC-A-Shield-Con-Kit Shield continuity wire
• FOSC-450A-MULTI-4/7
• FOSC-450A-3-DROP-KIT
2 General
2.1
Kit content
2.4
Port capacity
3 Closure preparation
3.2 Loosen and turn the two metal latches that secure the frame. Take out
the frame.
Note
: if a gel seal is already installed loosen the gel seal by turning the
tail of the seal counter-clockwise until the seal is loose.
Summary of Contents for FOSC-450A
Page 15: ...15 ...