M0201AJB
Era
™
Medium Power Carrier Access Point Installation Guide
© October 2018 CommScope, Inc.
Page 47
Installing CAP Ms
Connect the CAP M Cables
Complete the following procedures in the order in which they are presented. Unless otherwise noted, each
procedure is applicable to a singular CAP M (not in a cascade), or to a Primary or Secondary CAP M in a
cascade.
•
"Obtain the Required Cable Material” on page 47
•
"Connect the CAP M to an RF Antenna” on page 48
•
"Connect the CAP M to a Classic CAN or TEN” on page 48
•
"Connect a Secondary CAP M (Optional)” on page 48
•
"Connect an External Ethernet Device (Optional)” on page 49
.
Obtain the Required Cable Material
Contact your local CommScope sales representative to obtain the following components, as required, for this
installation.
•
Per the installation plan, obtain either Single Mode Fiber (SMF) or Multi Mode Fiber (MMF) that is of
sufficient length to reach from the CAP M to the Classic CAN or TEN.
•
Obtain at least one Optical OCTIS Kit (PN 7770612). All installations require one Optical OCTIS Kit, which
is included in the CAP M shipment. If cascading a Secondary CAP M, a second Optical OCTIS Kit is required.
•
Obtain SFP+ Module pairs that are appropriate for this installation.
Modules and the maximum range for each.
•
If connecting an external Ethernet device such as WiFi or IP camera, an Ethernet OCTIS Kit (PN 7760652)
and appropriate CAT cable for the device.
Do not remove protective caps from any of the connectors until instructed to do so.
Table 10.
Supported SFP+ Modules
CommScope PN Description
Maximum Range
Notes
7660511
SFP+, 10GBase-SR, Multi Mode
OM3
OM4
300m
400m
One placed in the TEN and paired with another in the
Classic CAN
7680813
SFP+, 10GBase-LR, Single Mode
10km
One placed in the TEN and paired with another in the
Classic CAN