Era
™
Medium Power Carrier Access Point Installation Guide
M0201AJB
Page 46
© October 2018 CommScope, Inc.
Installing CAP Ms
Grounding the CAP M
1
Connect an earth-bonding cable to the grounding bolt connections on the outside of the CAP M chassis, as
shown below.
2
Loosen the M6 hex nut(s), and then connect the
earth-bonding cable between the two washers as
shown to the right.
3
Secure the earth-bonding cable by tightening the
M6hex nut(s) that you loosened in the preceding step.
4
Connect the other end of the earth-bonding cable to a
suitable permanent ground per local electrical code
practices.
5
Follow the steps in
The CAP M must be grounded.
Do not use the grounding bolts to connect an external device.
Grounding bolts
Plain washers
M6
hex
nut
Locking
ring
M6
hex
nut
Earth-Bounding
cable