commercial cool CWAM10W6C User Manual Download Page 8

ENGLISH

Page 8

SAFETY GUIDELINES

To prevent injury to the user or other people and property damage, the following 
instructions must be followed. Incorrect operation due to ignoring of instructions 
may cause harm or damage.

ALWAYS DO THIS

NEVER DO THIS

ENERGY SAVE

•  Your air conditioner 

should be used in such a 
way that  it is protected 
from moisture. e.g. 
condensation,  splashed 
water, etc. Do not place or 
store your air conditioner 
where it can fall or be 
pulled into water or any 
other liquid. Unplug 
immediately.

•  Always transport your air 

conditioner in a vertical 
position and stand on a 
stable, level surface during 
use.

•  Turn off the product when 

not in use.

•  Always contact a qualified 

person to carry out 
repairs. If the supply cord 
is damaged it must be 
repaired by a qualified 
technician.

•  Keep an air path of at least 

12 inches. all around the 
unit from walls, furniture 
and curtains.

•  If the air conditioner is 

knocked over during 
use, turn off the unit and 
unplug from the power 
supply immediately.

•  Do not operate your air 

conditioner in a wet room such 
as a bathroom or laundry room.

•  Do not touch the unit with 

wet or damp hands or when 
barefoot.

•  Do not press the buttons on 

the control panel with anything 
other than your fingers.

•  Do not remove any fixed 

covers. Never use this appliance 
if it is not working properly, 
or if it has been dropped or 
damaged.

•  Never use the plug to start and 

stop the unit.

•  Always use the switch on the 

control panel to start or shut off 
the unit.

•  Do not cover or obstruct the 

inlet or outlet grilles.

•  Do not use hazardous chemicals 

to clean or come into contact 
with the unit. Do not use 
the unit in the presence of 
inflammable substances 
or vapour such as alcohol, 
insecticides, petrol,etc.

•  Do not allow children to 

operate the unit unsupervised.

•  Do not use this product for 

functions other than those 
described in this instruction 
manual.

•  Use the unit in the 

recommended room size.

•  Locate the unit where 

furniture cannot obstruct 
the air flow.

•  Keep blinds/curtains 

drawn.

• Keep the filters clean.

•  Keep doors and windows 

closed to keep cool air in 
and warm air out.

SAFETY INFORMATION

Summary of Contents for CWAM10W6C

Page 1: ...Window Air Conditioner User Manual MODEL MOD LE MODELO CWAM10W6C CWAM12W6C...

Page 2: ...ENGLISH Page 2...

Page 3: ...staple your sales receipt to your manual for warranty coverage SAFETY INFORMATION Important Safety Instructions 4 Battery Information 5 Grounding Instructions 6 Power Cord Use 7 Safety Guidelines 8 SE...

Page 4: ...DO NOT USE AN ADAPTER OR AN EXTENSION CORD 7 Do not block airflow around the air conditioner 8 Always unplug the air conditioner before servicing it or moving it 9 Do not install or use the air condi...

Page 5: ...um coin batteries out of the reach of small children coin cell batteries can be accidentally ingested If ingested these batteries may leak harmful contents causing chemical burns perforation of soft t...

Page 6: ...must be plugged into an outlet that is properly installed and grounded Avoid the use of three prong adapters or cutting off the third grounding prong in order to accommodate a two prong outlet This is...

Page 7: ...ages 4 The power supply cord will now supply electricity to the unit NOTE Do not use this device to turn the unit on or off Always make sure the reset button is pushed in for correct operation The pow...

Page 8: ...and unplug from the power supply immediately Do not operate your air conditioner in a wet room such as a bathroom or laundry room Do not touch the unit with wet or damp hands or when barefoot Do not p...

Page 9: ...ances cut or remove the third ground prong from the power cord Do not change the plug on the power cord of the air conditioner Aluminum house wiring may present special problems consult a qualified el...

Page 10: ...d windows on some models 10 3 4 1 12 Weather stripping 5 This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful int...

Page 11: ...ently pull back the center to free the open end See Fig 1 B Slide the free end I section of the panel directly into the cabinet as shown in Fig 2 Slide the panel down Be sure to leave enough space to...

Page 12: ...INDOWS Drive 1 2 12 7 mm locking screws through the frame lock and into the window sash Fig 8B NOTE Before driving the screws use a drill to drill 5 holes through the holes in the frame lock and frame...

Page 13: ...imize air leaks between the room air conditioner and the window opening trim the weather stripping with a proper length peel off the protective backing and plug any gaps if needed Fig 14 IF AC IS BLOC...

Page 14: ...Once the room has cooled adjust the thermostat to the setting you find most comfortable 5 Make sure that the air flow inside and outside are not obstructed by anything AIR DIRECTIONAL LOUVERS The lou...

Page 15: ...en counter clockwise rotation of 45 degrees make sure the groove is aligned with the lock sign as shown below WARNING 1 Battery must be disposed of properly Do not short circuit or dispose of in the f...

Page 16: ...etting program will be cancelled on some models SLEEP BUTTON Press this button to activate the Sleep mode This function is available on COOL HEAT or AUTO mode only and maintain the most comfortable te...

Page 17: ...by pressing the Sleep button again TO ADJUST FAN SPEEDS Press Fan button to select the Fan Speed in four steps Auto Low Med or High Each time the button is pressed the fan speed mode is shifted For s...

Page 18: ...ncrements up to 24 hours The control will count down the time remaining until start The selected time will register in 5 seconds and the system will automatically revert back to display the previous t...

Page 19: ...nit without the air filter CABINET CLEANING Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or washed with a cloth damp...

Page 20: ...ely in accordance with an industry recognized assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of...

Page 21: ...temperature to a Lower setting Air directional louvers positioned improperly Position louvers for better air distribution Front of units is blocked by drapes blinds furniture etc restricts air distri...

Page 22: ...or replacement 14 Service calls to instruct you how to use your product 15 Service calls to repair or replace the house fuse reset the circuit breaker or correct the wiring in the house REPAIR OR REP...

Page 23: ...ENGLISH Page 23...

Page 24: ...2019 Commercial Cool is a W Appliance Company All Rights Reserved 0119...

Reviews: