SET UP & USE

OPERATING INSTRUCTIONS

The unit can be controlled by the unit 
control alone or with the remote.

NOTE: 

 The outline of the operation panel 
is based on typical model, the 
function is the same with your air 
conditioner while some difference 
may exist in appearance.

TO TURN UNIT ON OR OFF:

 

Press ON/OFF button to turn unit on or off. 

NOTE:  

The unit will initiate automatically 
the Energy Saver function under 
Cool, Dry and Auto modes.

TO CHANGE TEMPERATURE 
SETTING: 

Press UP/DOWN button to change 
temperature setting.

NOTE:

  Press or hold either UP or 

DOWN button until the desired 
temperature is shown on the 
display.

This temperature will be automatically 
maintained anywhere between 62˚F (17˚C) 
and 86˚F(30˚C). If you want the display to 
read the actual room temperature, see To 
Operate on Fan Only section.

SLEEP FEATURE:

 

Press Sleep button to initiate the 
sleep mode. In this mode the selected 
temperature will increase by 2˚F/1 (or 2)˚C 
30 minutes after the mode is selected. The 
temperature will then increase (cooling) by 
another 2˚F/1 (or 2)˚C after an additional 
30 minutes. This new temperature will 
be maintained for 6 or 7 hours before 
it returns to the originally selected 
temperature. This ends the Sleep mode 
and the unit will continue to operate as 
originally programmed. The Sleep mode 
program can be cancelled at any time 
during operation by pressing the Sleep 
button again.

TO ADJUST FAN SPEEDS:

 

Press Fan button to select the Fan Speed 
in four steps-Auto, Low, Med or High. Each 
time the button is pressed, the fan speed 
mode is shifted. For some models, the fan 
speed cannot be adjusted.

CHECK FILTER FEATURE:

 

Press Check filter button to initiate this 
feature. This feature is a reminder to clean 
the Air Filter for more efficient operation. 
The LED(light) will illuminate after 250 
hours of operation. To reset after leaning 
the filter, press the Check Filter button and 
the light will go off.

ENERGY SAVER FEATURE:

 

Press Energy saver button to initiate this 
function. This function is available on 
COOL, DRY, AUTO (only AUTO-COOLING 
and AUTO-FAN) modes. The fan will 
continue to run for 3 minutes after the 
compressor shuts off. The fan then cycles 
on for 2 minutes at 10 minute intervals until 
the room temperature is above the set 
temperature, at which time the compressor 
turns back on and Cooling Starts.

TO SELECT THE OPERATING 
MODE:

To choose operating mode, press Mode 
button. Each time you press the button, a 
mode is selected in a sequence that goes 
from Auto, Cool, Dry and Fan. The indicator 
light beside will be illuminated and 
remained on once the mode is selected.
The unit will initiate automatically the 
Energy Saver function under Cool, Dry, 
Auto (only Auto-Cooling and Auto-Fan) 
modes.

TO OPERATE ON COOL MODE:

 

Choose Cool Mode to set the cooling 
function. Use the Up and Down buttons 
to choose the desired temperature. When 
Cool Mode is selected, the fan speed can 
be adjusted by pressing the fan button.

Summary of Contents for CWAM10W6C

Page 1: ...Window Air Conditioner User Manual MODEL MOD LE MODELO CWAM10W6C CWAM12W6C...

Page 2: ...ENGLISH Page 2...

Page 3: ...staple your sales receipt to your manual for warranty coverage SAFETY INFORMATION Important Safety Instructions 4 Battery Information 5 Grounding Instructions 6 Power Cord Use 7 Safety Guidelines 8 SE...

Page 4: ...DO NOT USE AN ADAPTER OR AN EXTENSION CORD 7 Do not block airflow around the air conditioner 8 Always unplug the air conditioner before servicing it or moving it 9 Do not install or use the air condi...

Page 5: ...um coin batteries out of the reach of small children coin cell batteries can be accidentally ingested If ingested these batteries may leak harmful contents causing chemical burns perforation of soft t...

Page 6: ...must be plugged into an outlet that is properly installed and grounded Avoid the use of three prong adapters or cutting off the third grounding prong in order to accommodate a two prong outlet This is...

Page 7: ...ages 4 The power supply cord will now supply electricity to the unit NOTE Do not use this device to turn the unit on or off Always make sure the reset button is pushed in for correct operation The pow...

Page 8: ...and unplug from the power supply immediately Do not operate your air conditioner in a wet room such as a bathroom or laundry room Do not touch the unit with wet or damp hands or when barefoot Do not p...

Page 9: ...ances cut or remove the third ground prong from the power cord Do not change the plug on the power cord of the air conditioner Aluminum house wiring may present special problems consult a qualified el...

Page 10: ...d windows on some models 10 3 4 1 12 Weather stripping 5 This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful int...

Page 11: ...ently pull back the center to free the open end See Fig 1 B Slide the free end I section of the panel directly into the cabinet as shown in Fig 2 Slide the panel down Be sure to leave enough space to...

Page 12: ...INDOWS Drive 1 2 12 7 mm locking screws through the frame lock and into the window sash Fig 8B NOTE Before driving the screws use a drill to drill 5 holes through the holes in the frame lock and frame...

Page 13: ...imize air leaks between the room air conditioner and the window opening trim the weather stripping with a proper length peel off the protective backing and plug any gaps if needed Fig 14 IF AC IS BLOC...

Page 14: ...Once the room has cooled adjust the thermostat to the setting you find most comfortable 5 Make sure that the air flow inside and outside are not obstructed by anything AIR DIRECTIONAL LOUVERS The lou...

Page 15: ...en counter clockwise rotation of 45 degrees make sure the groove is aligned with the lock sign as shown below WARNING 1 Battery must be disposed of properly Do not short circuit or dispose of in the f...

Page 16: ...etting program will be cancelled on some models SLEEP BUTTON Press this button to activate the Sleep mode This function is available on COOL HEAT or AUTO mode only and maintain the most comfortable te...

Page 17: ...by pressing the Sleep button again TO ADJUST FAN SPEEDS Press Fan button to select the Fan Speed in four steps Auto Low Med or High Each time the button is pressed the fan speed mode is shifted For s...

Page 18: ...ncrements up to 24 hours The control will count down the time remaining until start The selected time will register in 5 seconds and the system will automatically revert back to display the previous t...

Page 19: ...nit without the air filter CABINET CLEANING Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or washed with a cloth damp...

Page 20: ...ely in accordance with an industry recognized assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of...

Page 21: ...temperature to a Lower setting Air directional louvers positioned improperly Position louvers for better air distribution Front of units is blocked by drapes blinds furniture etc restricts air distri...

Page 22: ...or replacement 14 Service calls to instruct you how to use your product 15 Service calls to repair or replace the house fuse reset the circuit breaker or correct the wiring in the house REPAIR OR REP...

Page 23: ...ENGLISH Page 23...

Page 24: ...2019 Commercial Cool is a W Appliance Company All Rights Reserved 0119...

Reviews: