C: Align the hole in the top rail with those
in the top of the unit as shown in Fig. B
D: Secure the top rail to the unit with the
3/8 Screws as shown in Fig. C.
NOTE:
For safety reasons, all four (4)
screws MUST be securely fastened.
NOTE:
The top rail hardware and the
Fig. A, Fig. B and Fig. C are not
applicable to the units more than
10000 Btu/h. Before installing unit,
the top rail must be assembled on
the unit (For <10,000 Btu/h models
only).
INSTALL THE ACCORDION
PANELS
NOTE:
Top rail and Sliding Panels at each
side are offset to provide the proper
pitch to the rear of (5/16).
This is necessary for proper condensed
water utilization and drainage. If you are
not using the Side Panels for any reason,
this pitch to the rear must be maintained.
A. Place unit on floor, a bench or a table.
Hold the Accordion Panel in one hand
and gently pull back the center to free
the open end. See Fig.1
B. Slide the free end “I“ section of the panel
directly into the cabinet as shown in Fig.
2. Slide the panel down. Be sure to leave
enough space to slip the top and bottom
of the frame into the rails on the cabinet.
C. Once the panel has been installed on
the side of the cabinet, make sure it sits
securely inside the frame channel by
making slight adjustments. Slide the top
and bottom ends of the frame into the
top and bottom rails of the cabinet. Fig.
3.
D. Slide the panel all the way in and repeat
on the other side.
NOTE:
If storm window blocks AC, see Fig.
11.
3/ 4 (or 1/
Screws
(7)
2 )
Lock Frame
(2)
Sash Lock
(1)
Window sash
seal foam
(1)
3/8 Screws
(4)
Top Rail
(1)
Packaging
Fig.A
Top Rail
R1 hardware
(2)
R1 hardware(for
>
)
10000Btu/h models
only
R1 hardware
(for <
)
10000
Btu/h models
only
Lock Frame
(2)
(For Wooden
windows)
(For Vinyl-Clad
windows)
(on some models)
(10 *3/4 *1/12 )
Weather stripping
(5)
Fig. B
3/ 4 (or 1/
Screws
(7)
2 )
Lock Frame
(2)
Sash Lock
(1)
Window sash
seal foam
(1)
3/8 Screws
(4)
Top Rail
(1)
Packaging
Fig.A
Top Rail
R1 hardware
(2)
R1 hardware(for
>
)
10000Btu/h models
only
R1 hardware
(for <
)
10000
Btu/h models
only
Lock Frame
(2)
(For Wooden
windows)
(For Vinyl-Clad
windows)
(on some models)
(10 *3/4 *1/12 )
Weather stripping
(5)
Fig. C
3/ 4 (or 1/
Screws
(7)
2 )
Lock Frame
(2)
Sash Lock
(1)
Window sash
seal foam
(1)
3/8 Screws
(4)
Top Rail
(1)
Packaging
Fig.A
Top Rail
R1 hardware
(2)
R1 hardware(for
>
)
10000Btu/h models
only
R1 hardware
(for <
)
10000
Btu/h models
only
Lock Frame
(2)
(For Wooden
windows)
(For Vinyl-Clad
windows)
(on some models)
(10 *3/4 *1/12 )
Weather stripping
(5)
Fig. 1
"
Ⅰ
"section
Top Rail
Bottom Rail
Top Rail
Bottom Rail
Top left
Top right
Wooden Windows
INSIDE
OUTSIDE
H:About 3/4 to 1
(
for 5 to 8K);
3
H:About 1 to 1 /
(
for 10 to12K);
8
H
Vinyl-Clad Windows
INSIDE
OUTSIDE
H:About 3/4 to 1
(
for 5 to 8K);
Measure from the cabinet edge
3
H:About 1 to 1 /
(
for 10 to12K);
8
H
window
frame
Fig. 2
"
Ⅰ
"section
Top Rail
Bottom Rail
Top Rail
Bottom Rail
Top left
Top right
Wooden Windows
INSIDE
OUTSIDE
H:About 3/4 to 1
(
for 5 to 8K);
3
H:About 1 to 1 /
(
for 10 to12K);
8
H
Vinyl-Clad Windows
INSIDE
OUTSIDE
H:About 3/4 to 1
(
for 5 to 8K);
Measure from the cabinet edge
3
H:About 1 to 1 /
(
for 10 to12K);
8
H
window
frame
Fig. 3
"
Ⅰ
"section
Top Rail
Bottom Rail
Top Rail
Bottom Rail
Top left
Top right
Wooden Windows
INSIDE
OUTSIDE
H:About 3/4 to 1
(
for 5 to 8K);
3
H:About 1 to 1 /
(
for 10 to12K);
8
H
Vinyl-Clad Windows
INSIDE
OUTSIDE
H:About 3/4 to 1
(
for 5 to 8K);
Measure from the cabinet edge
3
H:About 1 to 1 /
(
for 10 to12K);
8
H
window