56
How to make a unit call and guard station call from a lobby phone
1. Press house number-E : to Household
2. Name search-Select Guard-E : to Guard Station
Other settings
1. P-Management Password -E-4-E : Surveillance Monitor Setting
(00: disabled, 01: enabled)
2. P-Management Password -E-5-E : Door Release Duration Setting
3. P-Management Password -E-6-E : Selecting Wiring Methods
(04: Common 4 wires, 06: Common 6 wires)
4. P-Management Password -E-7-E : Selecting Call Rings (00:MELODY, 01:BELL)
5. P-Management Password -E-8-E : Setting Video Out Impedance
(00: Short range, 01: Long range)
6. P-Management Password -E-17-E : Setting Voice Message of Unit Number
(00: enabled, 01: disabled)
7. P-Management Password -E-21-E : Setting the Call by Unit Line
8. P-Management Password -E-24-E : Setting the Forced Entry Notice Forwarding
Function
9. P-Management Password -E-25-E : Setting number of Call Rings
(00: continuous, 01: once)
10. P-Management Password -E-26-E : Setting the Voice Message Function
(00: enabled, 01: disabled)
11. P-Management Password -E-27-E : Setting the Automatic Security Call/Emergency
Call
(00: Automatic, 01: Emergency)
12. P-Management Password -E-30-Beep Volume-Voice Volume-E : Setting the
Volume of Voice and Beep Sound
P-Management password-E-34-E-Floor distributor ID-E-Input data-P : Setting Floor
Distributor data
13. P-Management Password -E-35-E : Setting Keypad LED On/Off
(00: When it’s just working, 01: Always)
14. P-Management Password -E-36-E : Setting Video Call On/Off
(00: disabled, 01: enabled)
Summary of Contents for DRC-703LC/RF1
Page 54: ...53 2 Door release by Extension panel button ...
Page 55: ...54 34 Door Release by Building Password or Management Password ...
Page 58: ...57 36 Wiring Information Guard interphone 1 GateView Guard Station 2 481 Guard Station ...
Page 59: ...58 entrance interphone DRC 703LC RF1 1 Using Coax Cable ...
Page 62: ...61 2 Using UTP Cat 5e Cable ...
Page 63: ...62 Wiring Method for CCTV and Sensor Connection ...
Page 67: ...66 Memo ...