31
16. Setting the Number of Call Ring Repetitions
•
P - Management Password - E - 26 - E – 0 – E : Voice message enabled.
•
P - Management Password - E - 26 - E – 1 – E : Voice message disabled.
•
This function enables/disables the Voice Message Function of DRC-703LC/RF1.
①
Press Program Button “P”
②
Press Management Passwords
③
Press Call Button “E” for call
④
Press number “26”
⑤
Press Call Button “E”
⑥
Select the mode
(0 : Voice message enabled)
(1 : Voice message disabled)
⑦
Press Call Button “E”