2
Visit our website for more details
www.CommandAccess.com
U.S. Customer Support
1-888-622-2377
Canada Customer Support
1-855-823-3002
MM4S S
witcheS
2 Beeps
3 Beeps
5 Beeps
6 Beeps
B
eepS
e
xplanation
S
olution
Over Voltage
Under Voltage
Retraction or Dogging
failure
Push to Set
> 30V unit will shut down. Check voltage & adjust to 24 V.
< 20V unit will shut down. Check voltage & adjust to 24 V.
Device physically binding during retraction or pulled from the dogged position.
Device is recording it’s new position and power mode after the 6th beep.
t
rouBleShooting
& D
iagnoSticS
4 Beeps
Failed Sensor
Verify all 3 sensor wires are installed correctly. Replace sensor if problem
persists by contacting office.
S
etting
ptS
Make sure to set PTS before finishing installation!
**
Important Info
**
• Input Voltage: 24VDC +/- 10%
• Wire gauge: Minimum 18 gauge
• Average Latch Retraction Current: 2 Amp
• Average Holding Current: 250 mA
High Torque Mode
• Average Latch Retraction Current: 600 mA
• Average Holding Current: 150 mA
Low Torque Mode
1. After 1
st
fail: 5 beeps then immediately attempts to retract again.
2. After 2
nd
fail: 5 beeps with pause in-between for 30 seconds then device
attempts to retract again.
3. After 3
rd
fail: 5 beeps every 7 minutes, device will not attempt to retract.
To Reset: Depress bar for 5 seconds at any time.
ON
OFF
OFF
OFF
ON
OFF
Low Torque
Standard Torque
Programming locked
ON ON High Torque
1
S
witch
p
rogram
2
• Average Latch Retraction Current: 900 mA
• Average Holding Current: 215 mA
Standard Torque Mode- S
hipS
S
tandard
T E C H N I C A L I N F O R M AT I O N
S
pecificationS
Step 1
-Select your preferred torque mode (ships in standard torque) Press the device push pad to the
desired setting.
(Recommend to fully depress and release 5%, giving the device a little room
for changing door conditions.)
Step 2
- While depressing the push pad, apply power. (i.e. presenting the credential to the reader).
Step 3
- Continue to keep pad depressed, the device will beep 6 times. After the beeps have stopped,
release the pad and now the adjustment is complete. If not to your liking repeat the three
steps. That’s all there is to it.
Step 4
- Once you found the right location, switch the dip switches to off to lock in programming.
rex S
witch
Rating:
.5A @24VAC
Configuration:
G
reen
- C
ommon
(C)
B
lue
- n
ormally
o
pen
(no)
G
ray
- n
ormally
C
losed
(nC)