background image

3

Ceiling Tile

Legend

Standard Placement

Module

GREEN 

CHANNEL 1 

LED

NORMALLY OPEN

DRY CONTACT FROM 

ACCESS CONTROL 

SYSTEM

NO VOLTAGE

LOCKING 

HARDWARE

+

-

CAT

Recommended Power Supplies:

All Command Access exit devices & field installable kits have been thoroughly  

cycle tested with Command Access power supplies at our factory. 

For more information 

click here 

or go to our website

Retrofit 2-pin Connector

The new 2-pin connector is used when retrofitting a older Command or 

Von Duprin installation so you can plug in to the exisiting connector.

PUSH N’ GO Connector

New

Exisitng

W

ire

 r

elease

W

ire

 a

ccess

Electrified Exit Device

Installation Example

U S   C U S T O M E R   S U P P O R T 1 - 8 8 8 - 6 2 2 - 2 3 7 7   |   W W W . C O M M A N D A C C E S S . C O M   |   C A   C U S T O M E R   S U P P O R T   1 - 8 5 5 - 8 2 3 - 3 0 0 2

Summary of Contents for LLP-UL-M KIT

Page 1: ...h go connector A B C D E Additional Information LLP UL M KIT INSERT Instructions The LLP UL M KIT is a field installable motorized latch pullback kit for the Hager 4500 LSDA9000 and Lawrence 8000 series 2 0 2 2 7 _ E U S c u s t o m e r s u p p o r t 1 8 8 8 6 2 2 2 3 7 7 w w w c o m m a n d a c c e s s c o m C A c u s t o m e r s u p p o r t 1 8 5 5 8 2 3 3 0 0 2 ...

Page 2: ...tion remove push pad down until beeping stops to reset If no obstruction the pad may have been pushed in too far during PTS calibration Recalibrate with the pad slightly out If problem persists verify the magnet is within 1 4 of the sensor at the end of travel Troubleshooting Diagnostics 4 Beeps Failed Sensor Verify all 3 sensor wires are installed correctly Replace sensor if problem persists by c...

Page 3: ...wer supplies at our factory For more information click here or go to our website Retrofit 2 pin Connector The new 2 pin connector is used when retrofitting a older Command or Von Duprin installation so you can plug in to the exisiting connector PUSH N GO Connector New Exisitng Wire Release Wire Access Electrified Exit Device Installation Example U S C U S T O M E R S U P P O R T 1 8 8 8 6 2 2 2 3 ...

Page 4: ... device has dogging will remove it if your device doesn t please skip ahead 3 steps 5 U S C U S T O M E R S U P P O R T 1 8 8 8 6 2 2 2 3 7 7 W W W C O M M A N D A C C E S S C O M C A C U S T O M E R S U P P O R T 1 8 5 5 8 2 3 3 0 0 2 Flip over the push pad and remove 2 phillips screws securing dogging assembly to baserail 6 Installation Instructions ...

Page 5: ...S S C O M C A C U S T O M E R S U P P O R T 1 8 5 5 8 2 3 3 0 0 2 Remove push pad end cap 9 Depress the push pad to extend dogging hole Slide motor mount attaching hook into dogging hole 10 Release push pad and line up holes on baserail with holes on motor mount underneath 11 1 2 Install 2 screws with allen wrench provided to secure the motor moun to the baserail 12 CONTINUED ...

Page 6: ...screws 13 Slide housing back onto baserail being cautious not to pitch any wires 14 While sliding housing back on make sure motor bracket fits between exsiting groves 15 Confirm motor has seated properly but see if the bottom bracket is sitting flush on the baserail 16 Attach to power and test to confirm motor is functioning 17 1 2 Re install 2 screws securing base rail to housing 18 CONTINUED ...

Page 7: ...ships in standard torque Press the device push pad to the desired setting Recommend to fully depress and release 5 giving the device room for changing door conditions Step 2 While depressing the push pad apply power i e presenting the credential to the reader Step 3 Continue to keep pad depressed the device will beep 6 times After the beeps have stopped release the pad and now the adjustment is co...

Reviews: