Step 1-

 Press the device push pad to the desired setting. (this can be fully depressed or less than fully     

depressed).

Step 2-

  While depressing the push pad, apply power. (i.e. presenting the credential to the reader).

Step 3-

 Continue to keep pad depressed, the device will beep 6 times, roughly 5 seconds. After the beeps 

have stopped, release the pad and now the adjustment is complete. If not to your liking repeat the 

three steps. That’s all there is to it. 

Setting PTS

2 Beeps

3 Beeps

5 Beeps

6 Beeps

Beeps

Explanation

Solution

Over Voltage

Under Voltage

Forced Release

Push pad is depressed. Device 

is re-adjusting

Over-travel or mechanical obstruction

> 28V unit will shut down. Check voltage & adjust to 24 V.

< 22V unit will shut down. Check voltage & adjust to 24 V. 

Device will automatically re-engage within 5 seconds.

Check to make sure the push pad is not stuck or catching 

 on anything. 

If mechanical obstruction, remove & push pad down until beeping stops 

to reset. If no obstruction, the pad may have been pushed in too far 

during PTS calibration. Recalibrate with the pad slightly out. If problem 

persists, verify the magnet is within 1/4” of the sensor at the end of 

travel.

Troubleshooting & Diagnostics

4 Beeps

Failed Sensor

Verify all 3 sensor wires are installed correctly. Replace sensor if problem 

persists by contacting  CAT tech support.

**Important Info**

Make sure to set PTS before finishing installation

Technical Information

# 2 0 2 2 7 _ E

U S   c u s t o m e r   s u p p o r t   1 - 8 8 8 - 6 2 2 - 2 3 7 7   |   w w w. c o m m a n d a c c e s s . c o m   |   C A   c u s t o m e r   s u p p o r t   1 - 8 5 5 - 8 2 3 - 3 0 0 2

mm4s switches

2

on
on

off

STANDARD TORQUE

HIGH TORQUE

PTS PROGRAMMING LOCKED

PTS PROGRAMMING on

off

Average Latch Retraction Current:  2 Amp

Average Holding Current:  250 mA

High Torque Mode

Average Latch Retraction Current: 1 Amp

Average Holding Current:  215 mA

Standard Torque Mode

SPECIFICATIONS

•  Input Voltage:   24VDC +/- 10%

•  Wire gauge:  Minimum 18 gauge

•  Direct wire run - no relays or access control 

units in-between power supply & module

1

7 Beeps

Summary of Contents for LLP-UL-M KIT

Page 1: ...h go connector A B C D E Additional Information LLP UL M KIT INSERT Instructions The LLP UL M KIT is a field installable motorized latch pullback kit for the Hager 4500 LSDA9000 and Lawrence 8000 series 2 0 2 2 7 _ E U S c u s t o m e r s u p p o r t 1 8 8 8 6 2 2 2 3 7 7 w w w c o m m a n d a c c e s s c o m C A c u s t o m e r s u p p o r t 1 8 5 5 8 2 3 3 0 0 2 ...

Page 2: ...tion remove push pad down until beeping stops to reset If no obstruction the pad may have been pushed in too far during PTS calibration Recalibrate with the pad slightly out If problem persists verify the magnet is within 1 4 of the sensor at the end of travel Troubleshooting Diagnostics 4 Beeps Failed Sensor Verify all 3 sensor wires are installed correctly Replace sensor if problem persists by c...

Page 3: ...wer supplies at our factory For more information click here or go to our website Retrofit 2 pin Connector The new 2 pin connector is used when retrofitting a older Command or Von Duprin installation so you can plug in to the exisiting connector PUSH N GO Connector New Exisitng Wire Release Wire Access Electrified Exit Device Installation Example U S C U S T O M E R S U P P O R T 1 8 8 8 6 2 2 2 3 ...

Page 4: ... device has dogging will remove it if your device doesn t please skip ahead 3 steps 5 U S C U S T O M E R S U P P O R T 1 8 8 8 6 2 2 2 3 7 7 W W W C O M M A N D A C C E S S C O M C A C U S T O M E R S U P P O R T 1 8 5 5 8 2 3 3 0 0 2 Flip over the push pad and remove 2 phillips screws securing dogging assembly to baserail 6 Installation Instructions ...

Page 5: ...S S C O M C A C U S T O M E R S U P P O R T 1 8 5 5 8 2 3 3 0 0 2 Remove push pad end cap 9 Depress the push pad to extend dogging hole Slide motor mount attaching hook into dogging hole 10 Release push pad and line up holes on baserail with holes on motor mount underneath 11 1 2 Install 2 screws with allen wrench provided to secure the motor moun to the baserail 12 CONTINUED ...

Page 6: ...screws 13 Slide housing back onto baserail being cautious not to pitch any wires 14 While sliding housing back on make sure motor bracket fits between exsiting groves 15 Confirm motor has seated properly but see if the bottom bracket is sitting flush on the baserail 16 Attach to power and test to confirm motor is functioning 17 1 2 Re install 2 screws securing base rail to housing 18 CONTINUED ...

Page 7: ...ships in standard torque Press the device push pad to the desired setting Recommend to fully depress and release 5 giving the device room for changing door conditions Step 2 While depressing the push pad apply power i e presenting the credential to the reader Step 3 Continue to keep pad depressed the device will beep 6 times After the beeps have stopped release the pad and now the adjustment is co...

Reviews: