Electrified Exit Device

Installation Example

Ceiling Tile

Legend

Standard Placement

Optional Placement

Module

GREEN 

CHANNEL 1 

LED

NORMALLY OPEN

DRY CONTACT FROM 

ACCESS CONTROL 

SYSTEM

NO VOLTAGE

LOCKING 

HARDWARE

+

-

CAT

Recommended Power Supplies:

All Command Access exit devices & field installable kits have been thoroughly 

cycle tested with Command Access power supplies at our factory. 

For more information 

click here 

or go to our website

Retrofit 2-pin Connector

The new 2-pin connector is used when retrofitting a older Command or 

Von Duprin installation so you can plug in to the existing connector.

PUSH N’ GO Connector

New

Exisitng

STRIPE WIRE 1/8”-3/16” 7 INSERT INTO WIRE ACCESS HOLES OF CONNECTOR.

WIRE RELEASE

WIRE ACCESS

# 2 0 0 9 2 _ F

U S   c u s t o m e r   s u p p o r t   1 - 8 8 8 - 6 2 2 - 2 3 7 7   |   w w w. c o m m a n d a c c e s s . c o m   |   C A   c u s t o m e r   s u p p o r t   1 - 8 5 5 - 8 2 3 - 3 0 0 2

Summary of Contents for CYLP-UL-M KIT

Page 1: ...Cap A B C D E F G Cordless Drill 2 Phillips head screwdriver CYLP UL M KIT INSERT Instructions The Command Access CYLP UL M KIT is a field installable motorized latch pullback kit for the Corbin 4000 5000 Yale 7000 series devices INSTALL VIDEO 2 0 0 9 2 _ F U S c u s t o m e r s u p p o r t 1 8 8 8 6 2 2 2 3 7 7 w w w c o m m a n d a c c e s s c o m C A c u s t o m e r s u p p o r t 1 8 5 5 8 2 3 ...

Page 2: ...n Current 1 Amp Average Holding Current 215 mA Standard Torque Mode SPECIFICATIONS Input Voltage 24VDC 10 Wire gauge Minimum 18 gauge Direct wire run no relays or access control units in between power supply module 2 Beeps 3 Beeps 5 Beeps 6 Beeps Beeps Explanation Solution Over Voltage Under Voltage Retraction or dogging Push to Start 30V unit will shut down Check voltage adjust to 24 V 20V unit w...

Page 3: ...nd Access power supplies at our factory For more information click here or go to our website Retrofit 2 pin Connector The new 2 pin connector is used when retrofitting a older Command or Von Duprin installation so you can plug in to the existing connector PUSH N GO Connector New Exisitng STRIPE WIRE 1 8 3 16 7 INSERT INTO WIRE ACCESS HOLES OF CONNECTOR WIRE RELEASE WIRE ACCESS 2 0 0 9 2 _ F U S c ...

Page 4: ...ecure the bracket to the device 5 Refer to this picture for the next 2 steps 4 Use the 2nd set screw to set the height of the attaching block You want the block to be level 6 If dogging assembly is present remove 2 screws and discard dogging assembly 2 2 0 0 9 2 _ F U S c u s t o m e r s u p p o r t 1 8 8 8 6 2 2 2 3 7 7 w w w c o m m a n d a c c e s s c o m C A c u s t o m e r s u p p o r t 1 8 5...

Page 5: ...hips in standard torque Press the device push pad to the desired setting Recommend to fully depress and release 5 giving the device room for changing door conditions Step 2 While depressing the push pad apply power i e presenting the credential to the reader Step 3 Continue to keep pad depressed the device will beep 6 times After the beeps have stopped release the pad and now the adjustment is com...

Reviews: