Adjust the four panel hook screws to keep the panel  
horizontal, and screw them up to the ceiling evenly.  

( Refer to   

Fig.5-10.3) 

Regulate the panel in the direction of the arrow in  

Fig.5-10.4 

slightly to fit the panel's center to the center of the ceiling's  
opening. Guarantee that hooks of four corners are fixed well. 

Keep fastening the screws under the panel hooks, until the  
thickness of the sponge between the body and the panel's  

panel should contact with the ceiling well. 

 (Refer to Fig.5-11) 

  

Fasten the rope of installation cover on the bolt of the  
installation cover.  

(Refer to Fig.5-14-left)  

Press the installation cover into the panel slightly.  

(Refer to  

Fig.5-14-right) 

     

Malfunction described in  

Fig.5-12 

 can be caused by  

inappropriate tightness the screw.  

If the gap between the panel and ceiling still exists after  
fastening the screws, the height of the indoor unit should  
be modified again.  

( Refer to Fig.5-13-left) 

You can modify the height of the indoor unit through the  
openings on the panel's four c orners, if the lift of the  
indoor unit and the drainpipe is not influenced  

(Refer to  

Fig.5-13-right). 

Hang the air-in grill to the panel, then connect the lead  
terminator of the swing motor and that of the control box  
with corresponding terminators on the body respectively. 

Relocate the air-in grill in the procedure of reversed order. 

Relocate the installation cover. 

Fig.5-10 

Tubing joint 

Outlet joint 

Hook panel 

Water-receiver 

Swing Motor 

Hook-bolt 

Cross-screwdriver 

Do not coil the wiring of the swing motor into the seal  
sponge. 

Install the panel 

Align the swing motor on the panel to the tubing joints of the  
body properly.  

( Refer to Fig.5-10) 

Fix hooks of the panel at swing motor and its opposite sides  
to the hooks of corresponding water receiver.  

( Refer to   

Fig.5-10.1)  

Then hang the other two panel hooks onto  

corresponding hangers of the body.  

( Refer to Fig.5-10.2) 

CAUTION 

6

panel sponge 

body 

Ceiling 

panel 

panel foam1  

air out 

Fan 

panel foam 2 

Loosen upper nut 

Adjust lower nut 

outlet foam 

Fig.5-12 

Fig.5-14 

Fig.5-11 

Fig.5-13 

Installation cover’s rope 

Tap Screw 

Slide the four sliders 

in the corresponding 

channel when installing 

the cover 

outlet has been reduced to about 0.16~0.24in.The edge of the  

0.16-0.24inch

Summary of Contents for CPP012CD(O)

Page 1: ...PA 12 TPA 18 TPA 24 TPA 36DU TPA 48DU Outdoor Unit CPP009CD O CPP012CD O CPP018CD O CPP024CD O CPP036CD O DU CPP048CD O DU If used as MULTI unit please refer to the Installation operation manuals pack...

Page 2: ...strong and firm location which is able to withstand the set s weight If the strength is not enough or installation is not properly done the set will drop to cause injury The appliance must be installe...

Page 3: ...not be sufficient enough to eliminate the noise The appliance is not intended for use by young children or infirm persons without supervision Don t install the air conditioner in the following locatio...

Page 4: ...vement without further notices Cautions on remote controller installation Remote controller Remote controller holder Mounting screw B ST2 9x10 C H CANCEL LOCK SET TEMPERATURE C AUTO COOL DRY HEAT FAN...

Page 5: ...INSPECTING AND HANDLING THE UNIT At delivery the package should be checked and any damage should be reported immediately to the service agent When handling the unit take into account the following 5...

Page 6: ...y by wrenching the nuts after having adjusted the body s position well Refer to Fig 5 5 Select the position of installation hooks according to the hook holes on the installation board positions on the...

Page 7: ...our corners if the lift of the indoor unit and the drainpipe is not influenced Refer to Fig 5 13 right Hang the air in grill to the panel then connect the lead terminator of the swing motor and that o...

Page 8: ...ge test Check whether the drainpipe is unhindered New built house should have this test done before paving the ceiling The unit with pump Remove the test cover and stow about 2000ml water to the water...

Page 9: ...g 5 19 Fig 5 18 One way Two way In case of one duct connection In case of two duct connection NOTE Fig 5 17 5 4 Install the distribution duct Conditioned air can be distributes by means of a distribut...

Page 10: ...direct sunlight If necessary install a blind that does not interfere with the air flow During the heating mode the water drained off the outdoor unit The condensate should be well drained away by the...

Page 11: ...lve of vacuum meter 2 Cut off the connection between pressure meter and vacuum pump 3 Close the vacuum pump Fig 6 7 NOTE All the pictures in this manual are for explanation purpose only They may be sl...

Page 12: ...ell with the tapes to prevent leakage Execute heat insulation work completely on both sides of the gas piping and the liquid piping Otherwise this can sometimes result in water leakage 1 2 3 5 6 7 4 B...

Page 13: ...orque N M Turn clockwise to close Stop Valve size Shaft valve body Cap Valve lid 6 4 5 4 6 6 Hexagonal 13 5 16 5 11 5 13 9 9 5 12 7 8 1 9 9 18 22 15 9 13 5 16 5 Hexagonal 23 27 22 2 27 33 Hexagonal wr...

Page 14: ...ion 3 The drain plug is used to empty the water receiver for maintenance of the air conditioner Please stuff it imposition at all times during operation to avoid leakage The body s pump pipe and the d...

Page 15: ...ment has to be connected with this power line For detailed installation acceptance please refer to your power supplier if restrictions do apply for products like washing machines air conditioners or e...

Page 16: ...impeded The heating insulation works well The ground wiring is connected correctly The length of the tubing and the added stow capacity of the refrigerant have been recorded The power voltage fits the...

Page 17: ...ding to the wiring scheme or it damages the unit Before obtaining access to terminals all supply circuits must be disconnected CAUTION Indoor Outdoor connection The power supply must comply with the r...

Page 18: ...ls TECHNICAL BULLETIN Heat Sink Compound Thermal Paste Make sure to use Heat Sink Compound not provided when replacing Mini Split electronic boards Clean up thoroughly old paste on chips located under...

Reviews: