ComfortStar CPP012CD(O) Installation Manual Download Page 4

3

installation manual 

3.    ATTACHED FITTINGS

Please check whether the following fittings are of full scope. If there are some spare fittings , please restore them carefully .  

Fig.3-1

Never throw or beat the controller.

Before installation, operate the remote controller to determine its location in a 
reception range.

Keep the remote controller at least 3.28ft apart from the nearest TV set or stereo 
equipment. (it is necessary to prevent image disturbances or noise interferences.)

Do not install the remote controller in a place exposed to direct sunlight or close to a 
heating source, such as a stove.

Note that the positive and negative poles are right positions when loading batteries.

This manual is subject to changes due to technological improvement without further 
notices.

Cautions on remote controller installation:         

Remote

controller

Remote controller

holder

Mounting screw B

ST2.9x10-C-H

CANCEL 

LOCK 

SET TEMPERATURE(°C) 

AUTO 
COOL 
DRY 
HEAT 

FAN 
HIGH 
MED 
LOW 

TEMP 

MODE 

SWING TIMER 

RESET 

ON/OFF 

  FAN  
SPEED 

VENT 

ECONOMIC  
 RUNNING 

(depending on the models)

QUANTITY 

Remote controller & Its Frame 
  

Drainpipe Fittings 

Installation Fittings 

SHAPE 

NAME 

12. Expansible hook 

2. Out-let pipe sheath 

3. Out-let pipe clasp 

4. Drain joint(on some models) 

5. Seal ring(on some models) 

10. Owner's manual 

11. Installation manual 

6. Remote controller 

7. Remote controller holder

8. Mounting screw(ST2.9×10-C-H)  

9. Alkaline dry batteries (AM4) 

13. Installation hook 

1. Installation paper board 

 

(on some models) 

 

(on some models) 

 

(on some models) 

 

 

 
 

Installation accessory

(The product you have might not be

 provided the following accessory)

(The product you have might not be

 provided the following accessory)

Summary of Contents for CPP012CD(O)

Page 1: ...PA 12 TPA 18 TPA 24 TPA 36DU TPA 48DU Outdoor Unit CPP009CD O CPP012CD O CPP018CD O CPP024CD O CPP036CD O DU CPP048CD O DU If used as MULTI unit please refer to the Installation operation manuals pack...

Page 2: ...strong and firm location which is able to withstand the set s weight If the strength is not enough or installation is not properly done the set will drop to cause injury The appliance must be installe...

Page 3: ...not be sufficient enough to eliminate the noise The appliance is not intended for use by young children or infirm persons without supervision Don t install the air conditioner in the following locatio...

Page 4: ...vement without further notices Cautions on remote controller installation Remote controller Remote controller holder Mounting screw B ST2 9x10 C H CANCEL LOCK SET TEMPERATURE C AUTO COOL DRY HEAT FAN...

Page 5: ...INSPECTING AND HANDLING THE UNIT At delivery the package should be checked and any damage should be reported immediately to the service agent When handling the unit take into account the following 5...

Page 6: ...y by wrenching the nuts after having adjusted the body s position well Refer to Fig 5 5 Select the position of installation hooks according to the hook holes on the installation board positions on the...

Page 7: ...our corners if the lift of the indoor unit and the drainpipe is not influenced Refer to Fig 5 13 right Hang the air in grill to the panel then connect the lead terminator of the swing motor and that o...

Page 8: ...ge test Check whether the drainpipe is unhindered New built house should have this test done before paving the ceiling The unit with pump Remove the test cover and stow about 2000ml water to the water...

Page 9: ...g 5 19 Fig 5 18 One way Two way In case of one duct connection In case of two duct connection NOTE Fig 5 17 5 4 Install the distribution duct Conditioned air can be distributes by means of a distribut...

Page 10: ...direct sunlight If necessary install a blind that does not interfere with the air flow During the heating mode the water drained off the outdoor unit The condensate should be well drained away by the...

Page 11: ...lve of vacuum meter 2 Cut off the connection between pressure meter and vacuum pump 3 Close the vacuum pump Fig 6 7 NOTE All the pictures in this manual are for explanation purpose only They may be sl...

Page 12: ...ell with the tapes to prevent leakage Execute heat insulation work completely on both sides of the gas piping and the liquid piping Otherwise this can sometimes result in water leakage 1 2 3 5 6 7 4 B...

Page 13: ...orque N M Turn clockwise to close Stop Valve size Shaft valve body Cap Valve lid 6 4 5 4 6 6 Hexagonal 13 5 16 5 11 5 13 9 9 5 12 7 8 1 9 9 18 22 15 9 13 5 16 5 Hexagonal 23 27 22 2 27 33 Hexagonal wr...

Page 14: ...ion 3 The drain plug is used to empty the water receiver for maintenance of the air conditioner Please stuff it imposition at all times during operation to avoid leakage The body s pump pipe and the d...

Page 15: ...ment has to be connected with this power line For detailed installation acceptance please refer to your power supplier if restrictions do apply for products like washing machines air conditioners or e...

Page 16: ...impeded The heating insulation works well The ground wiring is connected correctly The length of the tubing and the added stow capacity of the refrigerant have been recorded The power voltage fits the...

Page 17: ...ding to the wiring scheme or it damages the unit Before obtaining access to terminals all supply circuits must be disconnected CAUTION Indoor Outdoor connection The power supply must comply with the r...

Page 18: ...ls TECHNICAL BULLETIN Heat Sink Compound Thermal Paste Make sure to use Heat Sink Compound not provided when replacing Mini Split electronic boards Clean up thoroughly old paste on chips located under...

Reviews: