background image

Modulating 

Plug&Play Damper

Sleeping Space Airflow

Modulating 

Plug&Play Damper

Living Space Airflow

Optional Second
Battery Powered 

Wireless Temperature 

Sensor

Battery Powered 

Wireless Temperature 

Sensor

Optional Outdoor

Temperature Sensor

HVAC Equipment

Comfort365 Thermostat

WH11 or WH32 Wiring Hub

C365C42 or C365C42WF

Installed at equipment.

Installed in 

Wiring Hub

Existing thermostat Wires

25-foot Plug&Play Cables

Supplied with Dampers.

TS5WL Sensor installed

in Bedroom Hallway.

Required when using

dual fuel heat pumps.

TS5WL Sensor installed

in Master Bedroom

eLink ELR1 Plugin

Radio Module

4

2

IN

OUT

IN

OUT

P&P

P&P

GND

R

ODT

R

GND

+5V

C

ODT

C

+5V

SA

W/B

W/B

SA

SB

0

0

Y

Y

G

G

W2/E

W2/E

Y2

Y2

SB

Model TS3

Temperature Sensor

10K @ 77F

Made in USA

Wiring Diagram, Installation Using Battery Powered, Wireless Temperature Sensors

Number of wires used  in cable.

4

INSTALLER

Warranty

This thermostat is warranted to be free of defects due to workmanship 
or materials under normal use and service for a period of 5 years from 
date of installation and not longer than 6 years from manufacturing 
date code.

eControls, Inc. 26072 Merit Circle #110 / Laguna Hills, CA 92653

949-916-0945 Fax 949-458-8502 www.eControlsUSA.com

eControls

eControls

Living

Tu

Day

Sleeping

Living

Airflow %

COOL

Schedule

AUTO

FAN

MENU

MODE

Cool

Set To

SYSTEM

AM

365

Comfort

Summary of Contents for WH11

Page 1: ...Up to 6 dampers can be daisy chained to define the Upstairs Sleeping or Downstairs Living area One or two wired sensors can be used in the upstairs sleeping space For single sensor installations use...

Page 2: ...ayed on the thermostat User Airflow Control Manual Airflow Control can be enabled in the User Options Go to Menu Option 2 and turn off automatic airflow control Read entire manual before installing pr...

Page 3: ...ndicate when the damper is fully open green or fully closed red INSTALL UPSTAIRS DOWNSTAIRS DAMPERS Ensure that damper installation does not cause obstruction to the damper blade WIRING INSTRUCTIONS W...

Page 4: ...are provided HAND TIGHTEN Printed circuit board Brass washer Model TS510W Remote Temperature Sensor Model TS520W Remote Temperature Sensor Model TS520W Remote Temperature Sensor Wiring Hub WH11 or WH3...

Page 5: ...nstallation install the sensor on an interior wall about 4 feet above the floor and in a location that best senses the upstairs sleeping space temperature For a dual sensor installation install the se...

Page 6: ...needs to be documented for future reference Use the removable labels included with the thermostat to identify the sensors as 1 or 2 Place the labels on the front of the thermostat over the battery cov...

Page 7: ...m Hallway See Note 1 Required when using dual fuel heat pumps Sensor installed in Master Bedroom See Note 2 See Note 1 See Note 2 Use TS510W sensor for single sensor installations Use two TS520W senso...

Page 8: ...Link ELR1 Plugin Radio Module 4 2 IN OUT IN OUT P P P P GND R ODT R GND 5V C ODT C 5V SA W B W B SA SB 0 0 Y Y G G W2 E W2 E Y2 Y2 SB Model TS3 Temperature Sensor 10K 77F Made in USA Wiring Diagram In...

Reviews: